Operating modes (KX027-4 HI, KX030-4 HI)
Auxiliary port 1 is preset at the factory to allow four operating modes to be selected. Up to six operating modes
can be preset.
Whenever the auxiliary port button is pressed the operating mode changes by one level.
Select the mode of operation
If auxiliary port 1 is enabled on the display and control unit and an
operating mode has been selected, pressing the display selector
switch (1) shows the configured flow rate on the right auxiliary port
connector and then on the left auxiliary port connector for few sec-
onds on the display (2).
When the starter switch is turned to the RUN position, the most-recently used setting is activated.
Auxiliary port not active
Max. flow rate
One way flow
Limited flow volume
Mode 0
Indicator off
Mode 1
Indicator shines
Auxiliary port switch
Mode 2
Indicator blinks
Mode 3
Indicator blinks
Auxiliary
port
indicator 1
2
1