9 Function
Groups
9.1
Help Texts (running text)
Help Text menu
Select Help Text
ON
- a running text that has
started can be aborted with
any programming key
OFF
Select language for Help Text
English
Deutsch (German)
9.2 Signal
inputs
Menu Input Signal
Select measuring range
Meas. range 0 … 10 V
Meas. range 2 … 10 V
Meas. range -10 … +10 V
Meas. range 0 … 20 mA
Meas. range 4 … 20 mA
Select lower measuring range
limit
Input range depends on meas.
range [V / mA]
Select upper measuring range
limit
Input range depends on meas.
range [V / mA]
Select decimal point
(optical function only)
0
0.0
0.00
0.000
0.0000
Select input low value
Input range depends on meas.
range [V / mA]
Select display low value for
INP.LO.
Input range
-199999 … +999999 and DP
Select input high value
Input range depends on meas.
range [V / mA]
Select display high value for
INP.HI.
Input range
-199999 … +999999 and DP
Select Input Filter
The Filter function shows how
many measurement cycles are
used to determine the moving
average.
Input range 1 … 99 [cycles]
- with a value of 1 the filter
function is switched off
Select Start Delay after Power
On
(limit monitoring is processed
only after the programmed
time has expired)
Input range 0.0 ... 99.9 [sec]
Select local mains frequency
Mains frequency 50 Hz
Mains frequency 60 Hz
Input range depends on measuring range:
0 … 10 V = -0.500 … 10.500 [V]
2 … 10 V = 1.500 … 10.500 [V]
-10 … +10 V = -10.500 ... +10.500 [V]
0 … 20 mA = -0.500 … 21.000 [mA]
4 … 20 mA = 3.000 … 21.000 [mA]
The functions LO.LIM and HI.LIM limit the
editable range.
The value for HI.LIM must always be
greater than the value for LO.LIM.
Factory settings are highlighted grey.
Page 10
Содержание CODIX 565
Страница 6: ...5 Blockschaltbild 6 Anschlussbelegung Seite 6 ...
Страница 7: ...7 Bedienkonzept Betriebsmode deutsch Seite 7 ...
Страница 17: ...Ansteuerung bei steigendem Mess Signal Ansteuerung bei fallendem Mess Signal deutsch Seite 17 ...
Страница 28: ...5 Block diagram 6 Connections Page 6 ...
Страница 29: ...7 Operating concept Operating mode english Page 7 ...
Страница 31: ...Selecting Function Setting Parameters Accepting Parameters Function Groups Function Parameter english Page 9 ...
Страница 39: ...Control with incrementing measuring signal Control with decrementing measuring signal english Page 17 ...
Страница 66: ...Page 22 ...
Страница 72: ...5 Schema a blocchi 6 Collegamento Pagina 6 ...
Страница 94: ...5 Diagrama funcional 6 Conexiones Página 6 ...
Страница 109: ...español Página 21 ...
Страница 111: ......