![Kubler 573T Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/kubler/573t/573t_operating-manual_2008362020.webp)
R60726.0002 – Index 4
EN - page 20
5.1 General Menu
OPERATIONAL MODE
This parameter specifies the selected measuring function.
0 SINGLE
Single channel mode, only input 1
1 DUAL
Dual channel mode, input 1 and input 2 separated
2 IN1 + IN 2
Dual channel mode, sum of input 1 and input 2
3 IN1 – IN 2
Dual channel mode, difference of input 1 and input 2
4 IN1 x IN 2
Dual channel mode, multiplication of input 1 and input 2
5 IN1 / IN 2
Dual channel mode, input 1 divide by input 2
PIN PRESELECTION
This parameter defines the PIN-code to lock the quick start of the menu PRESELECTION VALUE for entering the
preselection values (master PIN 6079).
This Lock function is only useful in conjunction with active lock function in PIN PARAMETER.
0000
No lock
…
9999
Access after entering PIN-Code 9999
PIN PARAMETER
This parameter defines the PIN-code for lock function of all parameters (master PIN 6079).
0000
No lock
…
9999
Parameterization of the unit after entering PIN-code 9999
BACK UP MEMORY
0
NO
No back –up by power failure
1
YES
Backup by power failure, actual value will be saved, only by totalization
FACTORY SETTINGS
0
NO
No default values are loaded
1
YES
Load default values of all parameters (grey marked default values)