Page 12
www.kuebler.com
55..22..33C
Ch
ha
an
ng
giin
ng
g tth
he
e R
Ra
an
ng
ge
e LLiim
miittss
The given limits for the input range can be
entered as is, or adjusted.
Parameter Parameter
Possible range of values
Possible range of values
0 .. 10 V
–0.500 ... 10.500
–0.500 ... 10.500
2 .. 10 V
01.500 ... 10.500
01.500 ... 10.500
-10 .. +10 V –10.500 ... 10.500
–10.500 ... 10.500
0 .. 20 mA
–1.000 ... 21.000
–1.000 ... 21.000
4 .. 20 mA
03.000 ... 21.000
03.000 ... 21.000
If the measured signal falls below or ex-
ceeds the programmed value, then the
display alternates between
and
the measured value or between
and the the measured value.
Setting values out of the range is not pos-
sible. It is only possible to continue with
the set-up, using the
key, when the
settings are correct.
When the signal drops below the value
set here, then the signal alternates with
the message
U
Un
nd
de
err--rra
an
ng
ge
e:: if the signal is less then
–13,60 V than
appears in the
display.
Current values < 0.0 mA will not be
measured.
When the signal exceeds the value set
here, then the signal alternates with the
message
O
Ovve
err--rra
an
ng
ge
e if the signal is higher than
11.00 V or 21.5 mA, then
appears in the display..
Menu <–> Selection
Example: –5.000
Select digit
Set digit
Select digit
Set digit
Menu <–> Selection
Example: 9,000
Select digit
Set digit
LLo
ow
we
err lliim
miitt
U
Up
pp
pe
err lliim
miitt
press the
key to accept the selection
press the
key to accept the selection