2. Inputs
INP A
Start input (depending on the input mode cho-
sen)
INP B
Time meter Start/Stop or gate input (depending
on the input mode chosen)
RESET
Dynamic RESET input. Linked in parallel to the red
RESET key. Resets the counter to zero. Can be
adjusted individually for Counter 1 and Counter 2.
3. Selection of the displayed value
Pressing the right key allows switching between
the display of time meter 1 and the display of
time meter 2. Press the key briefly to display for
2 seconds the current function (“time1” or
“time2”). If, during this period of time, the right
key is pressed a second time, the device switch-
es to the next function and displays a confirma-
tion (“time1” or “time2”) for 2 seconds. Then, the
value of the selected function is displayed.
4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the
factory settings
7
e
n
g
lis
h
4.11 End of programming
The programming routine is
repeated once more. The val-
ues set until now can be
checked and modified.
The programming routine wil be
left and all values set will be
stored as new parameters.
Afterwards the device is ready
for operation.
4.10 RESET mode
(time meter)
manual reset via the red
RESET key and electrical reset
via the RESET input
no reset (red RESET key and
RESET input locked)
only electrical reset via the
RESET input
only manual reset via the red
RESET key
Electronic time meter with
2 time ranges
Codix 52U: basic operating mode
1. Description
• 6 digit time meter with Reset function
• Red LED display, character height 8 mm
• Display range 0 ... 999 999
• Leading zeros suppression
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Operation indicator: the decimal point of the
lowest digit blinks while the count is active
• Time meter operating modes:
– Counting while INP B is inactive “GAtE.Lo”
– Counting while INP B is active “GAtE.hi”
– Count Start/Stop with INP B edge (Inb.Inb)
– Count Start with INP A edge, count Stop with
INP B edge (InA.InB)
4.1 Polarity of the inputs
npn: switching for 0 V
pnp: switching for +UB
4.2 Switching on the 30 Hz filter
(INP A,INP B)
* where bounce occurs, e.g. with contacts
The filter provides input
damping*
30 Hz filter off (fmax)
Start/Stop inputs not damped
30 Hz filter on
Start/Stop inputs damped for
use with me cha nical switches
Содержание CODIX 52U
Страница 12: ......
Страница 34: ......
Страница 45: ...9 Dimensioni 22 2 0 3 x 45 0 6 mm Apertura d incastro Af3 DIN 74 1 11 italiano...
Страница 46: ......
Страница 57: ...11 espa ol 9 Dimensiones 22 2 0 3 x 45 0 6 mm Secci n del empotramiento Af3 DIN 74 1...