8
4.8 End of programming
The programming routine is
repeated once more. The val-
ues set until now can be
checked and modified.
The programming routine wil be
left and all values set will be
stored as new parameters.
Afterwards the device is ready
for operation.
Time unit: seconds (accuracy
depending on position of the
decimal point*)
Time unit: minutes (accuracy
depending on position of the
decimal point*)
Time unit: hours (accuracy
depending on position of the
decimal point*)
Time units: Hours:Minutes:Sec-
onds (decimal point setting is
ignored)
4.4 Operating mode
*0, 0.1, 0.01, 0.001 means: time measurement in
0, 0.1, 0.01, 0.001 time units
4.5 Decimal point
The decimal point defines the
resolution of the pro gram med
time unit.
0 1
0.0 1/10 (0,1)
0.00 1/100 (0,01)
0.000 1/1000 (0,001)
4.7 RESET mode
(time meter 2)
manual reset via the red
RESET key and electrical reset
via the RESET input
no reset (red RESET key and
RESET input locked)
only electrical reset via the
RESET input
only manual reset via the red
RESET key
4.6 RESET mode
(time meter 1)
manual reset via the red
RESET key and electrical reset
via the RESET input
no reset (red RESET key and
RESET input locked)
only electrical reset via the
RESET input
only manual reset via the red
RESET key
Start/Stop via Inp B. Counting
while Inp B (Gate) not active or
open
Start/Stop via Inp B.
Counting while Inp B (Gate)
active (High level with pnp; Low
level with npn)
Count Start/Stop via INP B
(LOW-HIGH edge with pnp;
HIGH-LOW edge with npn).
Every active edge changes the
counter status.
Count start via INP A, stop via
INP B. (LOW-HIGH edge with
pnp; HIGH-LOW edge with npn)
4.3 Input mode
(time meter)