* where bounce occurs, e.g. with contacts
2
Electronic display counter with
2 totalising ranges
1. Description
• 6-digit dislay counter with Reset function
• Red LED display, character height 8 mm
• Display range 0 ... 999 999
• Leading zeros suppression
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
2. Inputs
INP A
Dynamic count input Counter 1 and Counter 2.
RESET
Dynamic RESET input. Linked in parallel to the
red RESET key. Sets the counter to zero. Can be
adjusted individually for Counter 1 and Counter 2.
3. Selection of the displayed value
Pressing the right key allows switching between
the display of totaliser 1 and the display of
totaliser 2. Press the key briefly to display for 2
seconds the current function (“total1” or “total2”).
If, during this period of time, the right key is
pressed a second time, the device switches to
the next function and displays a confirmation
(“total1” or “total2”) for 2 seconds. Then, the
value of the selected function is displayed.
4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the
factory settings
-
S
u
b
je
c
t
to
c
h
a
n
g
e
w
it
h
o
u
t
p
ri
o
r
n
o
ti
c
e
-
4.1 Polarity of the inputs
npn: switching for 0 V
pnp: switching for +U
B
4.2 Switching on the 30 Hz filter
(INP A)
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0“ is not accepted!
4.3 Multiplying factor
(totaliser 1)
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0“ is not accepted!
4.4 Dividing factor
(totaliser 1)
The decimal point defines the
way of displaying the count val-
ues. It does not affect counting.
0
no decimal place
0.0
one decimal place
0.00
two decimal places
0.000
three decimal places
4.5 Decimal point
(totaliser 1)
4.6 RESET mode
(totaliser 1)
manual reset via the red
RESET key and electrical reset
via the RESET input
no reset (red RESET key and
RESET input locked)
only electrical reset via the
RESET input
only manual reset via the red
RESET key
The filter provides input damp-
ing*
30 Hz filter off (f
max
)
30 Hzfilter on