Slave
Master:
ID_HEX
DLC
DATA_HEX
580+NodeID
8
60
06
19
05
00
00
00
00
10ms ok
584
8
60
06
19
05
00
00
00
00
8. Electric installation
Please note the respective wiring diagram depending on the model.
Please note further that our product is already equipped with a terminating resistor.
9. Maintenance
Generally the Ants LEB01 does not demand high maintenance requirements.
In the course of routine servicing, proceed as follows:
•
Make sure the band is correctly directed between the sliding jaws (see “Direction of the
band”)
•
Control the sliding jaws for abrasion and dirt and replace as necessary. Also pay attention on the
second sliding jaw which is positioned inside the encoder.
• Clean the inside of the encoder carefully to remove dust and dirt.
• Examine the band for damages which could affect the result.
•
Check the tightening of the band. If it is insufficient because of the abrasion of the spring retighten it.
• Clean the band with a cloth during an inspection run.
10. Possible errors
No communication to elevator controller:
• Check support voltage.
• Make sure the connection to CAN-Bus is installed properly.
The Ants LEB01 can not be put into operational mode:
• Check if the band is correctly inserted.
•
Inspect the sliding jaws for abrasion.
11. Ordering information & spare parts
Any components (see „scope of delivery) can be reordered separately.
Therefore please contact the Kübler Group, Fritz Kübler GmbH.