11
english
5.1.5 Setting of the scale factor
Scale factor setting range from 00.0001 to
99.9999. Fixed decimal point set to 4
decimal places.
A ”0” setting is not accepted.
5.1.8 Preset 1
Preset 1 activated
Preset 1 disactivated and without function
5.1.6 Decimal point setting
The decimal point determines the number of
decimal places displayed. It is only used for
displaying purposes and has no influence on
the counting.
0
no decimal place
0.0
one decimal place
0.00
two decimal places
0.000
three decimal places
5.1.9 Shape of output 1
(only if preset 1 is activated)
Permanent signal
of output 1, activated
at count value
³
preset 1 in adding mode
and at count value
£
preset 1 in
subtracting mode
Permanent signal
of output 1, will
become passive at count value
³
preset 1
in adding mode and at count value
£
preset 1 in subtracting mode
Timed signal
of output 1 will become
passive at count value
³
preset 1 in
adding mode and at count value
£
preset 1
in subtracting mode
Timed signal.
of output 1 is activated at
count value
³
preset 1 in adding mode
and at count value
£
preset 1 in
subtracting mode
Manual (using the red push-button) and
electrical resetting
No resetting possible (red push-button
and reset input idle)
Only electrical resetting
Only manual resetting
5.1.7 Resetting mode
5.1.10 Duration of the transient output 1
(only if a
timed signal has been programmed in 5.1.9)
The duration can be set between 0.01 sec.
and 99.99 sec.
A 0.00 setting is not accepted
5.1.11 Shape of output signal 2
Permanent signal
of output 2, activated
at count value
³
preset 2 in adding mode
and at count value
£
0 in subtracting mode
Permanent signal
of output 2, will
become passive at count value
³
preset 2
in adding mode and at count value
£
0 in
subtracting mode
Timed signal
of output 2 will become
passive at count value
³
preset 2 in
adding mode and at count value
£
0 in
subtracting mode
Timed signal.
of output 2 is activated at
count value
³
preset 2 in adding mode
and at count value
£
0 in subtracting mode
5.1.12 Duration of the timed signal of output 2
(only if
a timed signal has been programmed in 5.1.11)
The duration can be set between 0.01 sec.
and 99.99 sec.
A 0.00 setting is not accepted
5.1.13 End of programming
Programming is carried out once more.
The values input can be checked and
modified.
Programming is complete and the values
input are taken over as new parameters.
Then the device is ready for operation.