4.6 Statistics

Configuration

Description

Port

TP - Twisted-Pair copper port on local unit
FX - Fiber port on local unit
Remote TP - TP port of the remote unit connected on the fiber link

Link

Port link status
Speed and duplex status with green background - port is link on
Down with red background - port is link down

Tx Bytes

Total of bytes transmitted on the port

Tx Frames

Total of packet frames transmitted on the port

Rx Bytes

Total of bytes received on the port

Rx Frames

Total of packet frames received on the port

Tx Errors

Total of error packet frames transmitted on the port

Rx Errors

Total of error packet frames received on the port

[Clear]

Click to reset all statistic counters

[Refresh]

Click to refresh all statistic counters

Содержание KGC-310-B

Страница 1: ...1 KGC 310 B KGC 310M B Web Smart Gigabit Ethernet Media Converter F W KGC 310M B Rev 1 01 up Installation Guide DOC 120528...

Страница 2: ...ves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For mo...

Страница 3: ...mits CISPR 22 CLASS B COMPLIANCE This device complies with EMC directive of the European Community and meets or exceeds the following technical standard EN 55022 Limits and Methods of Measurement of R...

Страница 4: ...P Address and Password for the Device 19 3 Functions 20 3 1Abbreviation 20 3 2 Converter Function 20 3 3 Link Fault Pass Through Function 21 3 4 Remote TP Status Monitoring Function 22 3 5 802 1Q Cont...

Страница 5: ...5 Appendix A Factory Default Settings 37 Appendix B Models Optical Specifications 39...

Страница 6: ...ets sent back This feature is helpful in checking connection quality of fiber link during installation Link Fault Pass Through This feature can force the link to shut down as soon as it notices that t...

Страница 7: ...us passes through between copper link and fiber link transparently Far End Fault function on fiber port Supports 802 3x flow control for full duplex and backpressure for half duplex Supports loopback...

Страница 8: ...uration Auto negotiation manual settings or software control Transmission rate 10Mbps 100Mbps 1000Mbps Duplex support Full Half duplex Network cable Cat 5 UTP 1000Mbps Fiber Port FX Mini GBIC SFP Comp...

Страница 9: ...ing SW5 Remote Twisted pair copper port monitoring SW6 Link fault pass through function setting Center Interface Interface For center chassis mounting Connector FutureBus Basic Functions MAC Addresses...

Страница 10: ...owser Management objects System configuration IP settings Name Password Port configuration control and status 802 1Q control settings Reboot restore factory default update firmware Models Special Feat...

Страница 11: ...unplug the product from the electrical outlet and replace the part or contact your trained service provider The power cable extension cable or plug is damaged An object has fallen into the product Th...

Страница 12: ...round the device Do not place heavy objects on the device Desktop mounting Wall mounting The device has one mounting wall on the bottom side to support wall mounting Din Rail mounting For a Din Rail c...

Страница 13: ...mmercial power voltage in your area The AC Power Adapter Specifications AC input power AC power voltage of your area options Rated AC120V 60Hz DC7 5V 1A DC5V 2A DC12V 0 8A Rated AC230V 50Hz DC7 5V 1A...

Страница 14: ...with auto negotiation function and full capability to support connection to any Ethernet devices The port performs a negotiation process for the speed and duplex configuration with the connected devi...

Страница 15: ...ceiver into the mini GBIC port Normally a bail is provided for every SFP transceiver Hold the bail and make insertion 3 Until the SFP transceiver is seated securely in the slot place the bail in lock...

Страница 16: ...fiber link during installation and check the test result displayed on the LED indicators The button may also be used to restore the software configuration settings to factory default values The opera...

Страница 17: ...TP Port in non auto 10Mbps Half duplex mode ON ON OFF Set TP Port in non auto 100Mbps Full duplex mode OFF OFF ON Set TP Port in non auto 100Mbps Half duplex mode ON OFF ON Set TP Port in auto 1000Mb...

Страница 18: ...Remark 1 LBT blinks to indicate loopback test in operation 2 LBT is ON for 10 seconds to indicate a test result is displayed on LBR LBR Loop Back TestResult ON Loopback Test OK Blink Loopback Test fai...

Страница 19: ...work Each unit should be desig nated a new and unique IP address in the network Refer to Web management interface for System Configuration The managed device is shipped with factory default password 1...

Страница 20: ...an IEEE 802 1Q tagged packet User Priority 3 bit field refer to the 802 1p priority CFI The Canonical Format Indicator for the MAC address is a 1 bit field VID VLAN identifier 12 bit field identifies...

Страница 21: ...each Cat 5 connection although the real fault occurs on the fiber connection exactly The following example illustrates a real link fault occurs on one Cat 5 and the link fault is passed to the other C...

Страница 22: ...eb management Configuration System Remote TP auto report Remote TP Status Display 1 The status are displayed on local LEDs TP1G TP100 TP10 TPFDX when LTP is OFF LED State Status LTP OFF Remote TP stat...

Страница 23: ...e settings are used together for packet egress tagging or untagging as table listed below Ingress Keep Tag Egress Insert Tag Packet Modification Enable Disable All packets are with no modification Dis...

Страница 24: ...This function allows to limit certain packets to pass from one link segment to another one VIDTable options Disable 802 1Q VIDfiltering is disabled Allowed VID Only the VLAN tagged packets with VIDs i...

Страница 25: ...yName The community string bound in a trap message Trap IP Address The IP address of the target SNMP trap host who is allowed to receive the traps SNMP Trap events The following events are defined for...

Страница 26: ...oftware and enter the IP address of the unit to which you want to connect The IP address is used as URL for the browser software to search the device URL http xxx xxx xxx xxx Factory default IP addres...

Страница 27: ...and other per port settings Monitoring Statistics List statistics for the local ports and remote TP port link status Maintenance Loopback Test Command to perform loopback test on fiber link Reboot Sys...

Страница 28: ...currently running H W Version The hardware version currently operating Management VLAN Set management VLAN information See next section VID VLAN ID configured for web management to the device CFI CFI...

Страница 29: ...isable all packets are allowed to pass with no 802 1Q control Enable 802 1Q control mechanism is activated for the conversion Jumbo Mode Enable disable Jumbo mode to support jumbo packets Disable supp...

Страница 30: ...VLAN VID settings is not zero The http server only accepts tagged manage ment packets matched Management VLAN VID and replies tagged packets with tag com posed of Management VLAN VID CFI and User Prio...

Страница 31: ...31 4 5 Ports Ports Configuration has three major parts as follows Port Configuration Port link status port operating mode port flow control 802 1Q Control 802 1Q Control per port settings...

Страница 32: ...Set port flow control function V set to enable 802 3x pause flow control for ingress and egress 802 1Q Control Function Ingress Drop Disable disable port ingress drop and admit all packet types Untag...

Страница 33: ...l 12 bit VID value Apply Click to apply the configuration change Refresh Click to refresh current configuration Close Click to close this window Notes 1 VID table is referred for filtering VLAN tagged...

Страница 34: ...on Down with red background port is link down Tx Bytes Total of bytes transmitted on the port Tx Frames Total of packet frames transmitted on the port Rx Bytes Total of bytes received on the port Rx...

Страница 35: ...layed on LEDs LBT and LBR 4 8 Reboot System This menu is used to reboot the device unit remotely with current configuration Starting this menu will make your current http connection lost You must rebu...

Страница 36: ...scription Filename Path and filename warp format Browse Click to browse your computer file system for the firmware image file Upload Click to start upload 4 11 Logout This menu is used to perform a lo...

Страница 37: ...VLAN CFI 0 Management VLAN User priority 0 IP Address 192 168 0 2 IP Subnet mask 255 255 255 0 Gateway IP 192 168 0 1 Name Null Password 123 SNMP Trap Disable CommunityName Null Trap IP Address 0 0 0...

Страница 38: ...38 802 1Q Filtering VID TABLE Disable VID n n 1 16 n...

Страница 39: ...SMF 10km W5310 LC Simplex SMF 10km W3520 LC Simplex SMF 20km W5320 LC Simplex SMF 20km W3410 LC Simplex SMF 10km W4310 LC Simplex SMF 10km W3410S SC Simplex SMF 10km W4310S SC Simplex SMF 10km Optica...

Отзывы: