www.ktindustries.net
c
oNtRoLS
PAGE | PAGE | PÁGINA
6
1. MIG Flux/Spool Gun Switch
2. Gas Quick Connect
3. Wire Spool (2 or 10lb)
4. Spool Knob
5. Feed Tensioner
6. Idler Arm
7. Wire Inlet Liner
8. Feed Roller Knob
9. Wire Feed Mechanism
2
3
1
4
5
6
7
8
9
INTERIOR CONTROLS
LOADING SPOOLS
LOOSEN
feed tensioner knob to allow idler arm to swing up
CHECK
feed roller for correct size and type groove to match wire size and type (flip or replace)
CUT
off bent, crimped, or rusted wire to ensure no burrs, sharp edges, or contamination are present
HOLD
tension on wire while guiding into feed guide (spool will unravel without tension)
ENSURE
wire is threaded into groove of feed roller
CLOSE
wire idler arm and rotate feed tensioner up
TIGHTEN
feed tensioner as required (2-3 flux core, 3-5 solid wire)
FEED ROLLER SETUP
Fits 10lb
Spool
Fits 2lb
Spool
Included spool adaptor fits 2lb and 10lb wire spools
Wire diameter stamped
on each side
Solid Wire
Flux
-Core Wire