5.6.3 Earthing
DANGER
Electrostatic charging
Explosion hazard!
Fire hazard!
Damage to the pump set!
▷
Connect the PE conductor to the earthing terminal provided.
5.7 Checking the direction of rotation
DANGER
Temperature increase resulting from contact between rotating and stationary
components
Damage to the pump set!
▷
Never check the direction of rotation by starting up the unfilled pump set.
▷
Separate the pump from the motor to check the direction of rotation.
WARNING
Hands inside the pump casing
Risk of injuries, damage to the pump!
▷
Always disconnect the pump set from the power supply and secure it against
unintentional start-up before inserting your hands or other objects into the
pump.
CAUTION
Incorrect direction of rotation with non-reversible mechanical seal
Damage to the mechanical seal and leakage!
▷
Separate the pump from the motor to check the direction of rotation.
CAUTION
Drive and pump running in the wrong direction of rotation
Damage to the pump!
▷
Refer to the arrow indicating the direction of rotation on the pump.
▷
Check the direction of rotation. If required, check the electrical connection and
correct the direction of rotation.
The correct direction of rotation of the motor and pump is clockwise (seen from the
motor end).
1.
Start the motor and stop it again immediately to determine the motor's
direction of rotation.
2.
Check the direction of rotation.
The motor's direction of rotation must match the arrow indicating the direction
of rotation on the pump.
3.
If the motor runs in the wrong direction of rotation, check the electrical
connection of the motor and the control system, if applicable.