7 Servicing/Maintenance
41 of 68
Vitaprime
7.2.2 Inspection work
DANGER
Excessive temperatures caused by friction, impact or frictional sparks
Explosion hazard!
Fire hazard!
Damage to the pump set!
▷
Regularly check the cover plates, plastic components and other guards of
rotating parts for deformation and sufficient distance from rotating parts.
DANGER
Static charging due to insufficient potential equalisation
Explosion hazard!
▷
Make sure that the connection between pump and baseplate is electrically
conductive.
7.2.2.1 Checking the clearances
1. Remove pump casing 101.
2. Examine pump casing 101 and impeller vanes for signs of seizure or rubbing
contact.
3. Smoothen any signs of seizure or rubbing contact using a polishing cloth.
4. Remove any burrs from the impeller vane.
5. Re-adjust the axial clearance / distance between pump casing 101 and impeller
230. (
ð
Section 7.5.2, Page 50)
6. Mount pump casing 101. (
ð
Section 7.5, Page 49)
7.2.2.2 Cleaning filters
CAUTION
Insufficient inlet pressure due to clogged filter in the suction line
Damage to the pump!
▷
Monitor contamination of filter with suitable means (e.g. differential pressure
gauge).
▷
Clean filter at appropriate intervals.
7.2.2.3 Checking the flushing liquid
Periodically check the flushing liquid for contamination. If necessary, drain the
flushing liquid. Clean the flushing system and fill it with new flushing liquid.
7.2.2.4 Checking the bearing seals
DANGER
Excessive temperatures caused by mechanical contact
Risk of explosion!
Damage to the pump set!
▷
Check correct seating of axial seal rings mounted on the shaft.
Only gentle contact of the sealing lip shall be established.
Содержание Vitaprime
Страница 66: ......
Страница 67: ......