4 Description of the Pump (Set)
17 of 68
Vitaprime
4.4 Design details
Design
▪
Standard design with materials to Regulation (EC) No. 1935/2004
▪
Design to ATEX
Design
▪
Side channel pump
▪
Horizontal installation
▪
One or two stages
▪
Self-priming
Pump casing
▪
Casing with transfer passages
Impeller type
▪
Open star impeller
Bearings
▪
Grease-packed deep groove ball bearing
Shaft seal
▪
Single mechanical seal to EN 12756
– Seal type T
3)
: pump-end seal with non-encapsulated spring surrounded by
fluid handled, uni-directional
▪
Double mechanical seal to EN 12756
– Seal type Q: back-to-back arrangement (pressurised barrier fluid)
Drive
▪
Efficiency class IE3 to IEC 60034-30
Standard design:
▪
KSB surface-cooled IEC three-phase current squirrel-cage motor
▪
50 Hz winding, 220 - 240 V / 380 - 420 V ≤ 2.20 kW
▪
50 Hz winding, 380 - 420 V / 660 - 725 V ≥ 3.00 kW
▪
60 Hz winding, 440 - 480 V ≤ 2.60 kW
▪
60 Hz winding, 440 - 480 V ≥ 3.60 kW
▪
Type of construction IM V1 ≤ 4.00 kW
▪
Type of construction IM V15 ≥ 5.50 kW
▪
Enclosure IP55
▪
Duty cycle: continuous duty S1
▪
Thermal class F with temperature sensor, 3 PTC thermistors
Explosion-proof version:
▪
KSB surface-cooled IEC three-phase current squirrel-cage motor
▪
50 Hz winding, 220 - 240 V / 380 - 420 V ≤ 1.85 kW
▪
50 Hz winding, 380 - 420 V / 660 - 725 V ≥ 2.50 kW
▪
Type of construction IM V1 ≤ 3.30 kW
▪
Type of construction IM V15 ≥ 4.60 kW
▪
Enclosure IP55 or IP54