7 Servicing/Maintenance
44 of 60
Sewabloc
7.4.9 Removing the wear plate (for D type impellers only)
914.12
135
101
Fig. 13:
Removing the wear plate
ü
The inside of the casing has been cleaned.
ü
The wear plate needs to be replaced as a result of visual inspection.
1. Unbolt the pump casing from the piping.
2. Undo hexagon socket head cap screws 914.12.
3. Remove wear plate 135 and O-rings 412.33/34.
7.5 Reassembling the pump set
7.5.1 General information/Safety regulations
WARNING
Improper lifting/moving of heavy assemblies or components
Personal injury and damage to property!
▷
Use suitable transport devices, lifting equipment and lifting tackle to move
heavy assemblies or components.
CAUTION
Improper reassembly
Damage to the pump!
▷
Reassemble the pump (set) in accordance with the general rules of sound
engineering practice.
▷
Use original spare parts only.
Sequence
Always re-assemble the pump in accordance with the corresponding general
assembly drawing or exploded view.
Sealing elements
Check O-rings for any damage and replace by new O-rings, if required.
Never use O-rings that have been made by cutting an O-ring cord to size and gluing
the ends together.
Make sure that the sealing elements and sealing surfaces are clean.
Assembly adhesives
Coat the locating surfaces of the individual components and screwed connections
with graphite or similar before reassembly.
Tightening torques
For reassembly, tighten all screws and bolts as specified in this manual.
Bearings
Only use specified bearings to DIN 625 (item 320.01/.02).
Table 17:
Bearings
Bearing bracket size
Grease-packed deep groove ball bearings, sealed
for life
B01
6307 - 2 Z - C3
B02
6311 - 2 Z - C3
B03
6314 - 2 Z - C3
Содержание Sewabloc Series