The pump has been completely separated from the motor.
✓
All components at the motor (e.g. coupling half at the motor shaft) have been
secured.
1.
Start the motor and stop it again immediately to determine the motor's
direction of rotation.
2.
Check the direction of rotation.
The motor's direction of rotation must match the arrow indicating the direction
of rotation on the pump.
3.
If the motor runs in the wrong direction of rotation, check the electrical
connection of the motor and the control system, if applicable.
5.11 Removing the transport lock
This type of transport lock is only used for vertical pumps with a product-lubricated
plain bearing.
160
901.17
Fig. 20: Transport lock
1.
Undo bolt 901.17 at cover 160.
2.
Connect a flushing line to the drilled hole in cover 160.
5 Installation at Site
Omega / Omega V
39 of 94