6B
6D
1M.1
1M.2
1M.1
1M.2
6D
6B.2
8A
26M.1
4M.2
4M.1
26M.2
4M.1
26M.1
6B.1
8A
Fig. 19: Auxiliary connections
Table 11: Auxiliary connections
Connection
Description
Type of
connection
1M.1
Connection for pressure measurement on
the suction side
G 1/2
1M.2
Connection for pressure measurement on
the discharge side
G 1/2
4M.1
Connection for temperature measurement
at the drive end
G 3/8
4M.2
Connection for temperature measurement
at the non-drive end
G 3/8
6B
Connection for pump drain on the suction side
G 1/2
6B.1
9)
Connection for pump drain on the suction side
G 1/2
6B.2
Connection for pump drain on the discharge side
G 1/2
6D
Connection for venting the pump
G 1/2
8A
Connection for leakage drain
G 3/4
26M.1
Connection for vibration measurement
at the drive end
M8
26M.2
Connection for vibration measurement
at the non-drive end
M8
5.9 Connection to power supply
DANGER
Incorrect electrical installation
Explosion hazard!
▷
For electrical installation, also observe the requirements of IEC 60079-14.
▷
Always use a motor protection switch for explosion-proof motors.
DANGER
Electrical connection work by unqualified personnel
Danger of death from electric shock!
▷
Always have the electrical connections installed by a trained and qualified
electrician.
▷
Observe regulations IEC 60364 and, for explosion-proof models, EN 60079.
▷
Observe the motor manufacturer's operating instructions.
9)
Applies to sizes 100 - 375, 150 - 290, 150 - 360, 150 - 605, 200 - 420, 200 - 520, 200 - 670, 250 - 600, 250 - 800, 300 - 300, 300
- 435, 300 - 560, 300 - 700, 300 - 860, 350 - 360, 350 - 430, 350 - 510
5 Installation at Site
Omega / Omega V
37 of 94