7 Servicing/Maintenance
50 of 72
HPK
1
2
3
Fig. 14:
Bearing bracket with constant level oiler
1
Constant level oiler
2
Screw plug
3
Bearing bracket
ü
A suitable container for the used oil is on hand.
1.
Place the container underneath the screw plug.
2.
Undo the screw plug (2) at the bearing bracket (3) and drain the oil.
3.
Once the bearing bracket (3) has been drained, re-insert and re-tighten the
screw plug (2).
4.
Re-fill with oil.
7.3 Drainage/cleaning
WARNING
Fluids, consumables and supplies which are hot and/or pose a health hazard
Hazard to persons and the environment!
▷
Collect and properly dispose of flushing fluid and any residues of the fluid
handled.
▷
Wear safety clothing and a protective mask, if required.
▷
Observe all legal regulations on the disposal of fluids posing a health hazard.
If the pump set has handled fluids whose residues could lead to corrosion damage in
the presence of atmospheric humidity or could ignite upon contact with oxygen, the
pump set must be neutralised, and anhydrous inert gas must be blown through the
pump to ensure drying.
Use connection 6B to drain the fluid handled (see drawing of auxiliary connections).
7.4 Dismantling the pump set
7.4.1 General information/Safety regulations
WARNING
Unqualified personnel performing work on the pump (set)
Risk of injury!
▷
Always have repair and maintenance work performed by specially trained,
qualified personnel.
WARNING
Hot surface
Risk of injury!
▷
Allow the pump set to cool down to ambient temperature.