7 Servicing/Maintenance
49 of 72
HPK
7.2.3.1.1 Intervals
Table 21:
Oil change intervals
Temperature at the
bearing
First oil change
All subsequent oil
changes
9)
up to 70
℃
After 300 operating hours Every 8500 operating hours
70 °C - 80 °C
After 300 operating hours Every 4200 operating hours
80 °C - 90 °C
After 300 operating hours Every 2000 operating hours
7.2.3.1.2 Oil quality
Table 22:
Oil quality
Designation
Symbol to DIN
51502
Features
CLP46 lubricating oil
to DIN 51517-3
or
HD 20W/20 SAE
□
Kinematic viscosity
at 40 °C
46±4 mm²/s
Flash point
(to Cleveland)
+175 °C
Solidification point
(pour point)
-15 °C
Application
temperature
10)
Higher than
permissible bearing
temperature
7.2.3.1.3 Oil quantity
Table 23:
Oil quantity
Bearing bracket
Oil quantity in l
P08s
4.5
P10as
4.0
P12s
4.0
7.2.3.1.4 Changing the oil
WARNING
Lubricants posing a health hazard and/or hot lubricants
Hazard to persons and the environment!
▷
When draining the lubricant take appropriate measures to protect persons and
the environment.
▷
Wear safety clothing and a protective mask, if required.
▷
Collect and dispose of any lubricants.
▷
Observe all legal regulations on the disposal of fluids posing a health hazard.
9)
At least once a year
10)
For ambient temperatures below -10 °C use a different suitable type of lubricating oil. Contact KSB.