6 Commissioning/Start-up/Shutdown
28 of 60
Ama-Drainer 4../5..
6.2.3.2 Minimum/maximum fluid level
Minimum level of fluid handled
CAUTION
Fluid level below the specified minimum
Damage to the pump set by cavitation!
▷
Never allow the fluid level to drop below the specified minimum.
The pump set is operational when the minimum fluid level is not lower than
dimension W
T
. This minimum fluid level must also be ensured during automatic
operation.
Table 7:
Minimum level of fluid handled
Type series
W
T min.
[mm]
Ama-Drainer .../10
60
Ama-Drainer .../11
120
Ama-Drainer .../35
120
Maximum fluid level (see name plate)
Max. immersion depth: 7 m
6.2.3.3 Temperature of the fluid handled
CAUTION
Incorrect temperature of the fluid handled
Damage to the pump (set)!
▷
Do not operate the pump (set) outside the specified temperature limits.
Never operate the pump at temperatures exceeding the ones stated below.
▪
Pump (set) in submerged condition:
– Maximum 40
℃
– For a short time (up to 3 minutes) maximum 90 °C
▪
Pump (set) outside the fluid handled:
– For limited time (up to 10 minutes) maximum 40
℃
– For a short time (up to 3 minutes) maximum 90 °C
6.2.3.4 Density of the fluid handled
The pump input power changes in proportion to the density of the fluid handled.
CAUTION
Excessive density of the fluid handled
Motor overload!
▷
Observe the information on fluid density in the data sheet.
▷
Make sure the motor has sufficient power reserves.
The pump (set) is suitable for handling chemically neutral waste water not containing
coarse substances, sand or faeces.