![KSB Ama-Drainer 4 Series Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/ksb/ama-drainer-4-series/ama-drainer-4-series_installation-and-operating-manual_2006540020.webp)
5 Installation at Site
20 of 60
Ama-Drainer 4../5..
5.3 Installing the pump set
l x b
h
Fig. 3:
Dimensions for installation
Table 6:
Recommended installation dimensions
Type series
l × b
3)
h
3)
[mm]
[mm]
Ama-Drainer 4..SE/10
500 × 500
500
Ama-Drainer 5..SD/10 K
Ama-Drainer 4..SD/35
550
Ama-Drainer 522/11
1. For transporting and lifting the pump observe the following notes.
2. If required, suspend the pump using a rope attached to the handle.
3. Place the pump on a solid surface.
4. Make sure that the float can move freely.
5.4 Piping
5.4.1 Connecting the piping
DANGER
Impermissible loads acting on the pump nozzles
Danger to life from escaping hot, toxic, corrosive or flammable fluids!
▷
Do not use the pump as an anchorage point for the piping.
▷
Anchor the pipes in close proximity to the pump and connect them properly
without transmitting any stresses or strains.
▷
Observe the permissible forces and moments at the pump nozzles.
▷
Take appropriate measures to compensate for thermal expansion of the piping.
NOTE
Installing check and shut-off elements in the system is recommended, depending on
the type of plant and pump. However, such elements must not obstruct proper
drainage or hinder disassembly of the pump.
3)
Minimum values
Содержание Ama-Drainer 4 Series