15
Movitec V 2,4,6,10,15 & 90
7
Installation instructions
7.1
Setting up the pump
ATTENTION
Make sure that the pump connections
are not over-stressed at the inlet and
outlet connections. Please see the table
below.
Table 11: Allowable forces Movitec V(S)F
Table 12: Allowable torque Movitec V(S)F
Table 13: Allowable forces Movitec VCF
Table 14: Allowable torque Movitec VCF
ATTENTION
For the values mentioned in the tables
above, it is assumed that they occur
simultaneously.
ATTENTION
Pumps which do not stand steady or
stable on their own, should be mounted
on a rigid and stable base.
ATTENTION
Locate the pump at the place with the
lowest risk for noise nuisance.
1.
Place and install the pump on a level, stable
surface in a dry and frost-free room.
2.
Make sure that sufficient air can reach the
cooling fan of the motor. For this purpose the
free space above the cooling fan should be at
least 1/4 of the diameter of the fan cover air
intake.
Type
DN
[mm]
Force [N]
Fx
Fy
Fz
Σ
F
V(S)F 2 B
25
3300
2400
1700
4400
V(S)F 4 B
25
3300
2400
1700
4400
V(S)F 6 B
32
3300
2400
1700
4400
V(S)F 10 B
40
4000
3100
3100
5900
V(S)F 15 B
50
4000
3100
3100
5900
V(S)F 90 B
100
3500
2500
1000
4400
20090283-C
Type
DN
[mm]
Moment [Nm]
Mx
My
Mz
Σ
M
V(S)F 2 B
25
280
95
210
400
V(S)F 4 B
25
280
95
210
400
V(S)F 6 B
32
280
95
210
400
V(S)F 10 B
40
440
180
200
500
V(S)F 15 B
50
440
180
200
500
V(S)F 90 B
100
750
500
625
1100
20090283-C
Type
DN
[mm]
Force [N]
Fx
Fy
Fz
Σ
F
VCF 2 B
25
9400
3200
3200
10400
VCF 4 B
25
9400
3200
3200
10400
VCF 6 B
32
9400
3200
3200
10400
VCF 10 B
40
11000
2000
6500
12900
VCF 15 B
50
11000
2000
6500
12900
VCF 90 B
100
60000
40000
40000
82500
20090283-C
Type
DN
[mm]
Moment [Nm]
Mx
My
Mz
Σ
M
VCF 2 B
25
600
300
360
800
VCF 4 B
25
600
300
360
800
VCF 6 B
32
600
300
360
800
VCF 10 B
40
460
460
1000
1200
VCF 15 B
50
460
460
1000
1200
VCF 90 B
100
3600
6100
4800
8600
20090283-C
ID3064
Figure 6: Allowable forces
20
0902
83-
A
Type
DN
[mm]
Moment [Nm]
Mx
My
Mz
Σ
M
Goodnal STP ST041 Disinfection & Outfall (KSB ATF Feed Pump Skid PU-0700-110
Q-Pulse Id VM405
Active 29/10/2013
Page 17 of 41