KSB ITUR AU Series Скачать руководство пользователя страница 7

 

 

AU

 

 

 

7

 

a

1

D

D

b

a

2

Ø

Ø

S

2

b

S

1

D

Ø

D

Ø

a

2

a

1

 

|a1-a2|

 and 

b

 

maximums

 [mm]

 

0-1500 1500-3000 3000-4000 

DØ 

[mm]

 

[rpm] [rpm]  [rpm] 

S

1

 

[mm]

S

2

 

[mm]

58-140 

0.20 0.15  0.10 4 

160-225 

0.30 0.20  0.15  6 

250-280 

0.35 0.30  --- 

 

Note: For other types of coupling, see their instructions 
manual. 

The equipment must always be aligned after 
mounting and preparing for start up. 

5.2.2 Monobloc 

groups 

Levelling 

Use a spirit level to level the equipment. Use wedges to alter 
the height at different points. The maximum deviation 
permitted is 0.2 mm/m. 

Pump - motor alignment 

The equipment is aligned at factory, and this alignment must 
never be lost. The following instructions must be followed 
when dismounting or returning the motor: 

-  Check that the flange support surface of the motor 

support and of the motor itself are perfectly clean and 
smooth. 

-  The motor shaft should easily enter the pump shaft (or 

bushing). If it is not, do not force assembly as this will 
damage the motor bearings. Check the alignment 
between both shafts and repair or replace them as 
necessary. 

5.3 Pipe 

joint 

In no case can the pump be used as a fixed point for the 
pipes. 

The pipe system must at no time exercise force in 
excess of the values shown in the chart in point 4.5 
(due to connection, thermal variation, etc) in the 

pump. 

The short pipes must be of at least the diameter of the pump 
connections. The diameter of long pipes is, in some cases, 
determined by economic criteria. 

Transition pieces at larger diameters must have an extension 
angle of around 8°, in order to prevent pressure drops. 

The convenience of installing foot valves 
when the pump is working in suction or 

retention when loaded, along with seal valves, will depend on 
the type of installation. 

Note 

The thermal expansions of the pipes must be compensated 
with suitable measures, in order not to exceed the maximum 
stresses permitted on the pump. 

The diameters of the pipes, valves and accessories must be 
calculated in line with the load losses envisaged in the 
installation, meaning the fluid speeds will be: 

-  Speed in the discharge pipe:  from 2 to 3 m/s 

-  Speed in the suction pipe: from 1 to 2 m/s 

Exceeding the admitted stresses of the pipes may 
lead to leaks in the pump and to the fluid escaping. 
Hazard of death with hot liquids! 

The suction and impulsion nozzle covers of the pump must be 
removed before connecting the pipes. 

Before starting up a new installation, it is necessary to 
thoroughly clean the tanks, pipes and accessories by brushing 
and blowing. Welding material, scales and other impurities are 
often cast off some time after. We recommend using an 
oversized sieve filter in suction in order to prevent dirt larger 
than that permitted by the pump from coming in. 

If hoses are fitted, these must be firmly in place 
before proceeding with start-up or during operation, 
in order to prevent any possible whiplash as a result 

of the pressure generated by the pump. 

High suction pressure may overload the bearings and 
lead to their overheating.  This circumstance must be 

avoided, to which end the suction pressure must not exceed 
that shown in the data sheet, either through manual control by 
the operators or through devices which shutdown the 
equipment in the event of excessive pressure. 

The pump must not work without liquid under any 
circumstance.  If this condition may come about, the 

installation must be fitted with safety devices which prevent 
the operation of the pump without liquid inside, or have 
automatic devices to discharge the minimum flow of the pump. 
See the section on minimum flow. 

5.3.1 Auxiliary 

connections 

The equipment is normally delivered mounted and ready for 
immediate operation, with only the hydraulic and exterior 
electrical connections being necessary. 

When using clean fluids, the cooling of the mechanical seal is 
by way of the recirculation of the pumping fluid (it is not 
necessary to inject exterior fluid). 

Auxiliary pipes are designed exclusively to 
support internal stresses due to the pressure 

of the circulating fluid, to which end it is forbidden to subject 
them to additional exterior stresses (e.g. for support, etc.) 

If the pumping liquid is fuel and the leak can lead to 
ignition, this contingency should be avoided through 

constant control of the seal tightness of the auxiliary pipe 
joints by the plant operator. 

Note 

Note 

Содержание AU Series

Страница 1: ...ins important instructions and warnings You must read them before mounting making the electrical connections and starting up You must also comply with the instructions for the components related to this pump Please remember that this Manual must be kept close to the motor pump group ...

Страница 2: ...justment 8 5 4 3 Rotation direction Check 8 6 START UP 8 6 1 FIRST START UP 9 6 1 1 Lubricant 9 6 1 2 Filling priming of the pump 9 6 1 3 Final control 9 6 1 4 Start up 9 6 1 5 Shutdown 10 6 2 SERVICE LIMITS 10 6 2 1 Switching frequency 10 6 2 2 Temperature of the liquid to be pumped Error Marcador no definido 6 2 3 Density of the liquid to be pumped 10 6 2 4 Viscosity of the liquid to be pumped 1...

Страница 3: ...hazard if not complied with are indicated with a general hazard sign Safety instructions which may involve a hazard to people and facilities if not complied with in accordance with ISO 7000 0434 Safety instructions to prevent electrical hazards in accordance with IEC 417 5036 Safety instructions which may affect the equipment and its operation if not complied with Note The details shown directly o...

Страница 4: ...o Directive 94 9 EC Individual pieces supplied as spare parts must be originals supplied and checked by KSB ITUR 3 Transport and storage 3 1 Transport and handling The transport and handling of the equipment must be carried out using suitable means in line with the weight to be supported The weight is generally shown on the delivery note or on the factory plate if it is not and the equipment canno...

Страница 5: ...oustic pressure level of these pumps is less than 92 dB A at 1 m in any operation point within the operation range without cavitation The acoustic power is less than 105 dB A 4 5 Forces and moments permitted in the nozzles CAST IRON OR BRONZE CASING 1 SUCTION IMPULSION FORCES N MOMENTS N m FORCES N MOMENTS N m SIZE PUMP Fx Fy Fz Mx My Mz Fx Fy Fz Mx My Mz AU 1 5 AU 2 AU 3 THREADED CONNECTIONS DO N...

Страница 6: ...nstructions manual for your transport bench if you do not have one already See annex 9 20 Cementing Pour an initial layer of mortar cement into the orifices of the bolts contacting throughout the periphery with the base of the base frame Once the mortar cement has set tighten the anchor pins in a balanced manner Note Connect the suction and impulsion nozzles to the installation and proceed with an...

Страница 7: ...pe from 2 to 3 m s Speed in the suction pipe from 1 to 2 m s Exceeding the admitted stresses of the pipes may lead to leaks in the pump and to the fluid escaping Hazard of death with hot liquids The suction and impulsion nozzle covers of the pump must be removed before connecting the pipes Before starting up a new installation it is necessary to thoroughly clean the tanks pipes and accessories by ...

Страница 8: ...a start up the line voltage must coincide with the voltage shown on the motor for delta start up D The six terminals indicated in the following diagram will be connected Connection to the star delta contactor 5 4 2 Time relay adjustment In the star delta start up of three phase motors it is necessary to ensure that the passage from star to delta takes place quickly Prolonged time will cause damage...

Страница 9: ...venting plug located in the casing or open a discharge pipe vent before the check valve 4 Partially open the suction valve until the liquid overflows through the vent 5 Close the vent 6 Fully open the suction valve 7 Check the rotation direction of the pump 8 Fully open the discharge valve EQUIPMENT IN SUCTION 1 Disconnect the voltage from the motor or batteries 2 Close the discharge valve 3 Remov...

Страница 10: ...mitted operation temperature is indicated in the order and in the ATEX conformity declaration If the pump is to work at a higher temperature or you do not have the data sheet please ask KSB ITUR 6 2 3 Density of the liquid to be pumped The power absorbed by the pump increases in direct proportion to the density of the impelled liquid In order to prevent overloading in the motor pump and coupling t...

Страница 11: ...lly The bearing support temperature is less than 40ºC in order to prevent burns to the hands To do this measure the temperature with a thermocouple The absence of oil grease in the bearing support may lead to a lack of lubrication of the lip seals which will come into dry contact with the shaft This contact may lead to a high shaft temperature which might cause ignition To prevent this regularly c...

Страница 12: ...mp frame must have returned to environmental temperature The pump frame must be depressurised and emptied Comply with all safety measures in accordance with 7 1 When working on the motor also take into account the rules and instructions of the manufacturer 7 4 2 Tubular coupling guards When dismounting follow the chapters on assembly but in reverse order 7 4 3 Coupling 1 Remove the coupling guard ...

Страница 13: ...ly approved quality bearings which are supplied as original spare parts Regularly check the correct state of the protector deflector and replace in the event of deterioration 7 5 Assembly 7 5 1 Tubular coupling guards 1 Install the distancer cylinder and seal using the clamps 1 1 2 Position the side cover 2 leaving the rims 3 in the upper section 3 Join the side cover 2 with the fastening screws 4...

Страница 14: ...ow of the cover 161 Check the correct location of pieces especially the seals and impellers and tighten the impeller nuts as shown in the chart in point 7 5 6 Note Do not forget to position all the safety and protection elements such as coupling guards before starting up the equipment The pump materials have been selected in accordance with the process fluid indicated in the datasheets If this flu...

Страница 15: ...he bearings With thermocouple Quarterly 2 5 12 7 Check tightness of connecting bolts for motor base frame pump base frame cover casing support support supplement flanges casing Manually Twice a year 17 8 COMPLETE PUMP CHECK Checking and dismounting the pump See point 7 of the manual Yearly 1 3 4 6 7 9 10 12 13 14 9 Check for wear of the impeller and rings Dismount casing visual inspection Yearly 1...

Страница 16: ...ghtness x x x Impeller obstructed deteriorated or imbalanced Dismount the impeller and inspect balance or change it x x Wear rings deteriorated or incorrectly assembled Dismount the rings and change them x Counter pressure too high Increase the rotation speed If this is not possible a larger impeller or larger pump needs to be assembled Please ask x Liquid viscosity or density greater than normal ...

Страница 17: ... foot 484 Fixing washer 914 Allen screw 210 Shaft 507 Deflector protection 920 Nut 230 Impeller 523 Shaft wearing sleeve 922 Impeller nut 320 Bearing 554 Flat washer 923 Bearing nut 331 Bearing bracket 636 Grease nipple 931 Lockwasger 341 Pedestal 637 Oil filling plug 932 Circlip 350 Bearing housing 643 Oil dipstick 940 Key 360 Bearing cover 800 Motor 400 Gasket 869 Coupling fastener AU M1 10 AU M...

Страница 18: ...507 800 903 2 901 2 411 2 412 902 1 554 1 920 2 902 2 920 3 554 2 523 901 1 019 AU M50 20 AU M50 25 Sectional C 1275 940 1 903 3 412 554 2 920 2 554 3 902 4 940 2 869 554 1 920 3 902 5 901 902 1 411 1 019 920 1 135 922 903 2 411 2 900 903 1 162 920 5 101 902 2 230 161 902 3 433 920 4 210 341 914 ...

Страница 19: ... 900 412 902 1 554 920 2 320 1 210 320 2 932 940 2 135 019 901 1 230 922 AU 50 20 AU 50 25 Sectional C 1269 903 1 162 920 1 101 902 2 903 5 230 161 902 3 433 420 637 643 331 360 2 940 1 903 3 412 554 920 3 507 901 2 400 360 1 320 1 903 4 210 320 2 940 2 901 1 902 1 411 1 019 920 2 135 922 903 2 411 2 900 ...

Страница 20: ...84 920 3 400 2 902 3 554 2 902 4 360 1 523 320 1 210 183 320 2 940 2 901 2 360 2 400 3 901 3 554 1 920 6 019 902 2 901 1 920 2 161 902 5 135 230 922 AU 80 15 AU 80 22 Sectional C 1271 162 903 1 101 902 1 411 1 433 940 1 161 554 2 320 1 636 320 2 923 903 2 411 2 412 902 3 920 2 932 2 331 210 932 1 931 940 2 922 135 902 2 554 1 920 1 019 901 1 230 900 ...

Страница 21: ...40 2 922 135 902 1 554 1 920 1 019 901 230 900 AU 150 25 AU 150 35 AU 150 45 Sectional C 1272 183 902 3 230 554 3 920 3 433 507 320 1 210 920 1 554 1 902 1 400 1 101 162 019 901 1 922 940 1 554 2 920 2 902 2 411 903 1 900 135 523 161 360 1 412 903 2 914 1 350 636 400 2 320 2 360 2 940 2 420 914 2 901 2 AU 200 40A AU 200 40B AU 200 55A AU 200 55B AU 200 68A AU 200 68B ...

Страница 22: ... 1334 183 902 3 230 554 3 920 3 433 507 320 1 637 920 1 554 1 902 1 400 1 101 162 019 901 1 922 940 1 554 2 920 2 902 2 411 1 903 1 900 135 523 161 411 2 412 903 2 210 350 400 2 643 320 2 360 940 2 420 901 2 554 4 901 3 ...

Страница 23: ...n sloping and clean in order to prevent any displacement If operation is by way of an electric motor with a pluggable connection check that the circuit breaker or operation selector is in shutdown position before connecting to the grid The start up instructions in the pump and motor manuals must be followed 9 2 3 Maintenance Apart from the particular instructions on maintenance of the pump and mot...

Страница 24: ...NDER CERTIFICATION PUMPS SERIES AU EC DECLARATION OF CONFORMITY KSB ITUR hereby declares under its responsibility that its aforementioned products when supplied with a motor to which this Declaration refers are in line with European Directive 98 37 EC on the approximation laws of the Member States on machinery Applied harmonised standards EN 292 Part 1 EN 292 Part 2 and EN 809 MANUFACTURER S DECLA...

Отзывы: