AU

 

 

 

2.6 Safety instructions for maintenance, 
inspection and assembly work 

The user must ensure that all maintenance, inspection and 
assembly tasks are carried out by authorised, qualified, 
specialised personnel who have been sufficiently informed 
through careful study of the instructions manual. 

The pump frame must have returned to environmental 
temperature. It must then be depressurised and emptied of 
liquid. 

It is a fundamental principle that any work on the machine 
must be carried out whilst it is shutdown.  It is essential to 
respect the pump shutdown procedure described in the 
instructions manual. 

All pumps or motor pumps which pump hazardous materials 
must be decontaminated. 

All safety and protection devices must be installed and put into 
operation as soon as work concludes. 

Before starting up again, all that described in the First Start-Up 
section must be followed. 

2.7  Modifications and arbitrary manufacture of 
spare parts 

The machine must not be modified or changed without prior 
agreement from the manufacturer. Only original spare parts 
and accessories approved by the manufacturer can guarantee 
safety. The use of other components may terminate any 
liability for consequences deriving from their use. 

2.8 

Unauthorised operation modes 

The safe service of the supplied pump can only be guaranteed 
through correct use, in line with section of the Instructions 
Manual. The operation limits established in the Datasheet 
must not be exceeded under any circumstance. 

2.9 

Warnings for equipment with marking 

 

KSB ITUR pumps marked with the ATEX plate are 
valid for group II category 2 and 3, zones 1, 21, 2 and 

22 temperature class as shown on the plate and Conformity 
Certificate. 

Reliability may be lost through incorrect use, poor 
connections or any modifications, however small. 

If the liquid is fuel, the pump frame pieces are 
constructed from ductile material and the impact test 

described in EN 13463-1 has been passed.

 

It is necessary to take into account the rules on the 
connection and use of electrical devices in hazardous 

areas, in particular national regulations on installation. Only 
qualified personnel who are familiar with these rules should 
handle this type of machine. 

Any repair made by the end user, unless explicitly 
approved by KSB ITUR, shall release the 

manufacturer from any liability relating to Directive 94/9/EC. 

Individual pieces supplied as spare parts must be originals, 
supplied and checked by KSB ITUR 

Transport and storage 

3.1 

Transport and handling 

The transport and handling of the equipment must be 
carried out using suitable means in line with the 
weight to be supported. The weight is generally 

shown on the delivery note or on the factory plate; if it is not, 
and the equipment cannot be handled safely, please contact 
KSB ITUR. 

Remember that the equipment must never be lifted using the 
ring bolts of the different items (e.g. motor and pump ring bolt), 
which are exclusively for independent transport. 

It is also important not to use the pump and 
pipe flanges or joining elements, e.g. 

couplings. 

Note 

If the equipment is to be lifted using straps, 
these must always be run underneath the 

motor and pump support. 

Note 

When the pumps are dismounted from their transport 
pallet, suitable means must be used to ensure the 
stability of the equipment, until it is finally secured at 

its definitive location. 

3.2 Provisional 

storage/Conservation 

During provisional storage, it is necessary to protect the parts 
with preservation products from contact with the low alloy 
liquid (e.g. grey casting, nodular casting, etc). Preservation 
products available on the sector market can be used, in line 
with the manufacturer's instructions on application and 
disposal. 

The pump, or motor pump, shall be placed in a dry site where 
the relative humidity is as constant as possible. 

When stored outside, it is necessary to keep the pump/motor 
pump in an impermeable box, ensuring it does not come into 
contact with external humidity. 

Protect the stored product from humidity, dirt, 
parasites and unauthorised access.  All 

openings must remain closed, and must not be opened until 
necessary during assembly. 

Note 

The shiny (mechanised) parts and surfaces of the pump must 
be protected from corrosion using silicone-free grease or oil. 

All equipment supplied on a transport bench (forklift 
truck, carriage, etc) should be secured using the 
envisaged attachment device or brake. Ask KSB 

ITUR for the specific instructions manual for your transport 
bench if you do not have one already (see annex  9.2). 

The electric motor must be disconnected, the 
connection cables removed and the terminal box 
closed with its cover on. 

The switchboards must be in vertical position and 
disconnected. 

4 Group 

description 

4.1 General 

description 

Horizontal centrifugal self-priming pump for the pumping of 
neutral or aggressive liquids, clean liquids or with solids in 
suspension. 

 

 

Содержание AU Series

Страница 1: ...ins important instructions and warnings You must read them before mounting making the electrical connections and starting up You must also comply with the instructions for the components related to this pump Please remember that this Manual must be kept close to the motor pump group ...

Страница 2: ...justment 8 5 4 3 Rotation direction Check 8 6 START UP 8 6 1 FIRST START UP 9 6 1 1 Lubricant 9 6 1 2 Filling priming of the pump 9 6 1 3 Final control 9 6 1 4 Start up 9 6 1 5 Shutdown 10 6 2 SERVICE LIMITS 10 6 2 1 Switching frequency 10 6 2 2 Temperature of the liquid to be pumped Error Marcador no definido 6 2 3 Density of the liquid to be pumped 10 6 2 4 Viscosity of the liquid to be pumped 1...

Страница 3: ...hazard if not complied with are indicated with a general hazard sign Safety instructions which may involve a hazard to people and facilities if not complied with in accordance with ISO 7000 0434 Safety instructions to prevent electrical hazards in accordance with IEC 417 5036 Safety instructions which may affect the equipment and its operation if not complied with Note The details shown directly o...

Страница 4: ...o Directive 94 9 EC Individual pieces supplied as spare parts must be originals supplied and checked by KSB ITUR 3 Transport and storage 3 1 Transport and handling The transport and handling of the equipment must be carried out using suitable means in line with the weight to be supported The weight is generally shown on the delivery note or on the factory plate if it is not and the equipment canno...

Страница 5: ...oustic pressure level of these pumps is less than 92 dB A at 1 m in any operation point within the operation range without cavitation The acoustic power is less than 105 dB A 4 5 Forces and moments permitted in the nozzles CAST IRON OR BRONZE CASING 1 SUCTION IMPULSION FORCES N MOMENTS N m FORCES N MOMENTS N m SIZE PUMP Fx Fy Fz Mx My Mz Fx Fy Fz Mx My Mz AU 1 5 AU 2 AU 3 THREADED CONNECTIONS DO N...

Страница 6: ...nstructions manual for your transport bench if you do not have one already See annex 9 20 Cementing Pour an initial layer of mortar cement into the orifices of the bolts contacting throughout the periphery with the base of the base frame Once the mortar cement has set tighten the anchor pins in a balanced manner Note Connect the suction and impulsion nozzles to the installation and proceed with an...

Страница 7: ...pe from 2 to 3 m s Speed in the suction pipe from 1 to 2 m s Exceeding the admitted stresses of the pipes may lead to leaks in the pump and to the fluid escaping Hazard of death with hot liquids The suction and impulsion nozzle covers of the pump must be removed before connecting the pipes Before starting up a new installation it is necessary to thoroughly clean the tanks pipes and accessories by ...

Страница 8: ...a start up the line voltage must coincide with the voltage shown on the motor for delta start up D The six terminals indicated in the following diagram will be connected Connection to the star delta contactor 5 4 2 Time relay adjustment In the star delta start up of three phase motors it is necessary to ensure that the passage from star to delta takes place quickly Prolonged time will cause damage...

Страница 9: ...venting plug located in the casing or open a discharge pipe vent before the check valve 4 Partially open the suction valve until the liquid overflows through the vent 5 Close the vent 6 Fully open the suction valve 7 Check the rotation direction of the pump 8 Fully open the discharge valve EQUIPMENT IN SUCTION 1 Disconnect the voltage from the motor or batteries 2 Close the discharge valve 3 Remov...

Страница 10: ...mitted operation temperature is indicated in the order and in the ATEX conformity declaration If the pump is to work at a higher temperature or you do not have the data sheet please ask KSB ITUR 6 2 3 Density of the liquid to be pumped The power absorbed by the pump increases in direct proportion to the density of the impelled liquid In order to prevent overloading in the motor pump and coupling t...

Страница 11: ...lly The bearing support temperature is less than 40ºC in order to prevent burns to the hands To do this measure the temperature with a thermocouple The absence of oil grease in the bearing support may lead to a lack of lubrication of the lip seals which will come into dry contact with the shaft This contact may lead to a high shaft temperature which might cause ignition To prevent this regularly c...

Страница 12: ...mp frame must have returned to environmental temperature The pump frame must be depressurised and emptied Comply with all safety measures in accordance with 7 1 When working on the motor also take into account the rules and instructions of the manufacturer 7 4 2 Tubular coupling guards When dismounting follow the chapters on assembly but in reverse order 7 4 3 Coupling 1 Remove the coupling guard ...

Страница 13: ...ly approved quality bearings which are supplied as original spare parts Regularly check the correct state of the protector deflector and replace in the event of deterioration 7 5 Assembly 7 5 1 Tubular coupling guards 1 Install the distancer cylinder and seal using the clamps 1 1 2 Position the side cover 2 leaving the rims 3 in the upper section 3 Join the side cover 2 with the fastening screws 4...

Страница 14: ...ow of the cover 161 Check the correct location of pieces especially the seals and impellers and tighten the impeller nuts as shown in the chart in point 7 5 6 Note Do not forget to position all the safety and protection elements such as coupling guards before starting up the equipment The pump materials have been selected in accordance with the process fluid indicated in the datasheets If this flu...

Страница 15: ...he bearings With thermocouple Quarterly 2 5 12 7 Check tightness of connecting bolts for motor base frame pump base frame cover casing support support supplement flanges casing Manually Twice a year 17 8 COMPLETE PUMP CHECK Checking and dismounting the pump See point 7 of the manual Yearly 1 3 4 6 7 9 10 12 13 14 9 Check for wear of the impeller and rings Dismount casing visual inspection Yearly 1...

Страница 16: ...ghtness x x x Impeller obstructed deteriorated or imbalanced Dismount the impeller and inspect balance or change it x x Wear rings deteriorated or incorrectly assembled Dismount the rings and change them x Counter pressure too high Increase the rotation speed If this is not possible a larger impeller or larger pump needs to be assembled Please ask x Liquid viscosity or density greater than normal ...

Страница 17: ... foot 484 Fixing washer 914 Allen screw 210 Shaft 507 Deflector protection 920 Nut 230 Impeller 523 Shaft wearing sleeve 922 Impeller nut 320 Bearing 554 Flat washer 923 Bearing nut 331 Bearing bracket 636 Grease nipple 931 Lockwasger 341 Pedestal 637 Oil filling plug 932 Circlip 350 Bearing housing 643 Oil dipstick 940 Key 360 Bearing cover 800 Motor 400 Gasket 869 Coupling fastener AU M1 10 AU M...

Страница 18: ...507 800 903 2 901 2 411 2 412 902 1 554 1 920 2 902 2 920 3 554 2 523 901 1 019 AU M50 20 AU M50 25 Sectional C 1275 940 1 903 3 412 554 2 920 2 554 3 902 4 940 2 869 554 1 920 3 902 5 901 902 1 411 1 019 920 1 135 922 903 2 411 2 900 903 1 162 920 5 101 902 2 230 161 902 3 433 920 4 210 341 914 ...

Страница 19: ... 900 412 902 1 554 920 2 320 1 210 320 2 932 940 2 135 019 901 1 230 922 AU 50 20 AU 50 25 Sectional C 1269 903 1 162 920 1 101 902 2 903 5 230 161 902 3 433 420 637 643 331 360 2 940 1 903 3 412 554 920 3 507 901 2 400 360 1 320 1 903 4 210 320 2 940 2 901 1 902 1 411 1 019 920 2 135 922 903 2 411 2 900 ...

Страница 20: ...84 920 3 400 2 902 3 554 2 902 4 360 1 523 320 1 210 183 320 2 940 2 901 2 360 2 400 3 901 3 554 1 920 6 019 902 2 901 1 920 2 161 902 5 135 230 922 AU 80 15 AU 80 22 Sectional C 1271 162 903 1 101 902 1 411 1 433 940 1 161 554 2 320 1 636 320 2 923 903 2 411 2 412 902 3 920 2 932 2 331 210 932 1 931 940 2 922 135 902 2 554 1 920 1 019 901 1 230 900 ...

Страница 21: ...40 2 922 135 902 1 554 1 920 1 019 901 230 900 AU 150 25 AU 150 35 AU 150 45 Sectional C 1272 183 902 3 230 554 3 920 3 433 507 320 1 210 920 1 554 1 902 1 400 1 101 162 019 901 1 922 940 1 554 2 920 2 902 2 411 903 1 900 135 523 161 360 1 412 903 2 914 1 350 636 400 2 320 2 360 2 940 2 420 914 2 901 2 AU 200 40A AU 200 40B AU 200 55A AU 200 55B AU 200 68A AU 200 68B ...

Страница 22: ... 1334 183 902 3 230 554 3 920 3 433 507 320 1 637 920 1 554 1 902 1 400 1 101 162 019 901 1 922 940 1 554 2 920 2 902 2 411 1 903 1 900 135 523 161 411 2 412 903 2 210 350 400 2 643 320 2 360 940 2 420 901 2 554 4 901 3 ...

Страница 23: ...n sloping and clean in order to prevent any displacement If operation is by way of an electric motor with a pluggable connection check that the circuit breaker or operation selector is in shutdown position before connecting to the grid The start up instructions in the pump and motor manuals must be followed 9 2 3 Maintenance Apart from the particular instructions on maintenance of the pump and mot...

Страница 24: ...NDER CERTIFICATION PUMPS SERIES AU EC DECLARATION OF CONFORMITY KSB ITUR hereby declares under its responsibility that its aforementioned products when supplied with a motor to which this Declaration refers are in line with European Directive 98 37 EC on the approximation laws of the Member States on machinery Applied harmonised standards EN 292 Part 1 EN 292 Part 2 and EN 809 MANUFACTURER S DECLA...

Отзывы: