  Disconnect the device power supply. 

 

  Reconnect the device power supply. 

  Accessing  the  menu  SETUP  OF 

CONTROL LOOP. 

The  menu  “Setup  of  control  loop”  can  be  accessed  only  during  the  first  minute  of  reconnecting  the 

control panel by holding the 

 and 

 keys for 8 seconds. 

11  MAIN SCREEN 

 
 

 

 

 

 
 

12  OPERATING STATUS 

13  SETTING TARGET ROOM 

TEMPERATURE 

 
 

 

 

Operation 

of 

control loop. 

Operational 
setting for

 

control loop. 

 

The  room  temperature  currently  set  is  displayed 
when  the 

or 

arrow  is  pressed.  The 

temperature is highlighted with an orange border. 

Fast  heating  of 
tap water /

 

Fail-safe 

anti-

freeze mode

 

is active. 

Device 
maintenance of 

 

required. 

Desired  room  temperature  can  be  set  by  pressing 
the  arrow  again,  the  setting  is  confirmed  by 
pressing  the  icon,  or  is  automatically  confirmed 
after 8 seconds. 

Child safety lock 
is active. 

Multiple alarms /

 

errors active. 

 

 

 

Circulation  pump 
of the control

 

loop  is  currently 
active. 

 

8

sek

Menu / 

confirm 

External 

temperature 

Menu down / 

decrease value 

Time 

Back / 

cancel 

Room 

temperature 

Menu up / 

increase value 

Operating 

status 

8

sec 

Room temperature 

movement trend   

Содержание KT-2

Страница 1: ...Installation instruction and user manual KT 2 Spatial corrector The manual has to be handed over to the end user after installation ID 17 16 13 2960 03 1 2017 EN ...

Страница 2: ... 03 7 2017 Printed in Slovenia copyright Kronoterm d o o This document is copyrighted Any use outside the provisions of the copyright law without the permission of Kronoterm d o o is illegal and punishable by law All previous versions of this document are void We reserve the right to make changes and printing errors ...

Страница 3: ...age temperature of other rooms hallway living room The spatial corrector KT 2 is designed for installation on a flush mounted electrical socket 3M GW 24 403 PM The spatial corrector is used for fixed installation in closed and dry rooms Recommended mounting height is between 1 2 1 5 m from the ground Do not expose the spatial corrector KT 2 to direct sunlight do not install it in the area of air c...

Страница 4: ...bles from the spatial corrector KT 2 connected to terminals A B GND and 12 V to the RJ 45 connector Prepare the RJ 45 connector the same way as the one in the wiring diagram below Connect it to the connecting terminal TS on the PLC in electric closet controller TERMOTRONIC UTP link between RJ 45 connector and KT 2 TIA EIA 568A connection of connector Cable colors RJ 45 A B GND 12V KT 1 1 2345 6 78...

Страница 5: ...nfirms valid settings with a multi tone beep 9 SYNCHRONISATION The device is synchronising wait a few minutes After a successful synchronisation the control panel is ready for use see Qick user guide NOTE Only one spatial corrector can control an individual control loop Incorrect operation occurs if two spatial correctors are installed on the same control loop 10 CHNGE OR RESETTING OF CONTROL LOOP...

Страница 6: ...set is displayed when the or arrow is pressed The temperature is highlighted with an orange border Fast heating of tap water Fail safe anti freeze mode is active Device maintenance of required Desired room temperature can be set by pressing the arrow again the setting is confirmed by pressing the icon or is automatically confirmed after 8 seconds Child safety lock is active Multiple alarms errors ...

Страница 7: ...played in the status bar to indicate an active child safety lock function Key operation is disabled The function is deactivated by pressing and holding buttons and f or 2 seconds simultaneously The function icon in status bar disappears and normal button operation is restored Child safety lock function prevents unauthorized access to the module The function can also be used to prevent unwanted but...

Страница 8: ...sult our technical assistance http www kronoterm com servis 18 Technical Device Information Dimensions HxWxD 80x80x8 6 mm The resolution of the temperature sensor 0 1 C Adjustable range 17 27 C Modbus RS485 connection Max 4 x KT 2 units can be connected to TT3000 Weather symbol Highest day time temperature forecast Air Humidity Day of the week Lowest night time temperature forecas Device current o...

Страница 9: ...9 Id 17 16 13 2960 03 7 2017 ...

Страница 10: ...Id 17 16 13 2960 03 7 2017 10 ...

Страница 11: ...11 Id 17 16 13 2960 03 7 2017 ...

Страница 12: ...nd place of production Kronoterm d o o Trnava 5e 3303 Gomilsko Tel 00386 3 703 16 20 Fax 00386 3 703 16 33 Web page www kronoterm com E mail info kronoterm com Customer support and service 00386 3 703 16 26 E mail servis kronoterm com ...

Отзывы: