D3S Static Node

 

User Manual 

 

 

 

 
 
 
 

Содержание D3S Static Node

Страница 1: ...D3S Static Node User Manual ...

Страница 2: ... recipient by accepting this document agrees that neither this document nor the information disclosed herein nor any part thereof shall be reproduced or transferred to other documents or used or disclosed to others for any other purpose except as specifically authorised in writing by Kromek Limited ...

Страница 3: ... 4 1 POWER SUPPLY AND GROUND TERMINALS 10 4 2 FUSES 10 4 3 BATTERY CONNECTOR 10 4 4 MAINTENANCE ETHERNET 10 4 5 EMBEDDED PC 10 4 6 MOUNTING FOR 3G 10 4 7 ANCHOR POINTS 10 5 SYSTEM CONFIGURATION 11 6 INSTALLATION AND WIRING 11 6 1 INSTALLATION ENVIRONMENT 12 6 2 MOUNTING METHOD 12 6 3 WIRING 13 6 3 1 Recommended Wiring 13 6 3 2 Anchor Points 13 6 3 3 Ethernet 14 7 MAINTENANCE 15 7 1 MAINTENANCE INS...

Страница 4: ...CTIONS C 19 8 6 STATUS PAGE 19 8 7 CONFIGURATION PAGE 21 8 8 NETWORK PAGE 22 8 9 LOG FILES PAGE ADVANCED MODE ONLY 22 8 10 ADVANCED MODE 22 8 10 1 Provisioning the Device 22 9 TECHNICAL APPENDIX 24 9 1 LIST OF D3S DETECTABLE ISOTOPES 24 10 SPECIFICATION 25 11 DISCLAIMER 27 11 1 FCC WARNING 27 ...

Страница 5: ...s Europe The product conforms with the relevant Community harmonisation legislation Radio Equipment Directive 2014 53 EU Low Voltage Directive 2014 25 EU Restriction of the use of certain hazardous substances directive 2011 65 EU The WEEE Directive 2 Symbols The following signal words and icons are used in this manual to indicate precautions when using the D3S Static Node The indicated precautions...

Страница 6: ...ions Alert Statements in this Manual A lithium battery is built into the D3S Static Node Lithium batteries are made from HAZARDOUS MATERIALS and care must be taken to avoid serious injury due to combustion explosion or burning If the battery is observed to swell in size become excessively hot or have very low capacity then disconnect power remove the device to an isolated safe place until battery ...

Страница 7: ...ns HAZARDOUS LIVE parts Follow all instructions outlined in the Installation section of this manual Special care must be used to use the anchor points for the mains cable to prevent risk of electrical shock 3 Precautions 3 1 Precautions for Safe Use The following precautions should be observed to ensure that the product is being used safely Do not use the product in environments subject to inflamm...

Страница 8: ...nstall the product in the following locations Locations subject to corrosive gases dust dirt metal powder or salt Locations where the specified ambient operating temperature is exceeded Locations subject to extreme temperature changes that may result in condensation Locations where the specified ambient operating humidity range is exceeded Locations where the product would be directly subjected to...

Страница 9: ...e gases dust dirt metal powder or salt Locations where the specified storage temperature range is exceeded Locations subject to extreme temperature changes that may result in condensation Locations where the specified storage humidity range is exceeded Locations where the product would be directly subjected to vibration or shock exceeding specifications Locations subject to contact with water oil ...

Страница 10: ...Critical 4 3 Battery Connector Provides connection to battery backup If battery needs replacement consult with your Kromek representative 4 4 Maintenance Ethernet Used for restoring factory settings and diagnosing faults 4 5 Embedded PC Manages the D3S Static Node and the communication with the Sigma network 4 6 Mounting for 3G Where the 3G module is fixed Module itself uses a USB connection to th...

Страница 11: ...en installing the D3S Static Node to ensure safe and proper performance The safety of any system incorporating the equipment is the responsibility of the assembler of the system Sigma Network D3S Static Node Ethernet Mains Power 115V AC 10 50 60Hz 230V AC 10 50 60Hz Circuit Breaker Sigma Network D3S Static Node Mains Power 115V AC 10 50 60Hz 230V AC 10 50 60Hz Circuit Breaker Cellular network ...

Страница 12: ...een 0 and 50 C Locations subject to corrosive or inflammable gases powder or salt Locations subject to direct vibration or shock Locations subject to direct sunlight Locations subject to submersion in water oil or chemicals 6 2 Mounting Method The casing design presents 4 x 2 6 mm holes for the installer to use as necessary The details are shown below ...

Страница 13: ...6A Mains supply If the device is to be installed in a situation that does not have 16A current limitation then a current limiting device must be installed rated to 16A Number of Cores 3 Voltage Rating 450V Current Rating 20A Cross Sectional Area 1 5mm2 Outer Diameter 9 2mm American Wire Gauge 15 Example Supply RS Components 744 0981 The wiring specification above is designed for standard single ph...

Страница 14: ...a cable restraint and cable clamp that should be used for this task If these restraints are missing or appear damaged any off the shelf cable restraint can be used but a unit must not be installed without them Every unit is shipped with restraints that should be used for this task If these restraints are missing or appear damaged any off the shelf cable restraint can be used but a unit must not be...

Страница 15: ... an authorised maintenance technician A lithium battery is built into the D3S Static Node Lithium batteries are made from HAZARDOUS MATERIALS and care must be taken to avoid serious injury due to combustion explosion or burning Never short circuit the positive and negative terminals of a battery or charge disassemble apply deforming pressure or expose the battery to fire The D3S Static Node contai...

Страница 16: ...atic Node Admin is designed for Kromek s range of static node devices giving easy connection and setup functions tailored to the detectors and their applications Static Node Admin allows for the configuration of static node devices including provision the device for Sigma network integration Configuration can be performed via direct connection to the primary network port 8 1 Connecting to a device...

Страница 17: ...opriate device in the list to connect Section 8 10 1 can be referred to if the device needs to be provisioned 8 2 Main Screen Overview Once connected to a device the main screen is displayed A Command bar Commands are applied to the connected device B Device summary A summary of details about the currently connected device More in depth details can be found on the Status page C Configuration Pages...

Страница 18: ... the device is restarted you will automatically be disconnected Any unsaved changes will be lost on disconnection Apply Software Update Apply a software update to the connected device from a file 8 4 Device Summary B A summary of the currently connected device is always shown on screen IP Address The IP address of the device currently connected This will always be 10 0 0 1 when connecting via the ...

Страница 19: ...configurable options for the device Editing values will not automatically be saved to the hardware device You must click the Save Changes button in the command bar for the settings to be applied Network Configure the primary network interface Log Files Advanced mode only Displays the application logs to aid in resolving issues 8 6 Status Page Displays the overall status of the device including sof...

Страница 20: ...me Synchronized Whether the device has acquired a valid time from an internet based time server In order to upload data to the Sigma network and ensure it is displayed correctly the device must have a valid time No data will be uploaded to the Sigma network until it has a validated time If the time is not synchronized then measurements will be cached rather than uploaded to the Sigma network f Sig...

Страница 21: ... connecting direct via the debug port d Auto Updates Enable disable the automatic checking and installation of software updates to the Static Node device 8 7 Configuration Page Main configuration for the device is performed on the configuration page All changes will only be applied when the Save Changes button is clicked 1 Main Settings a Device Serial The serial number of the Static Node Please n...

Страница 22: ...Mode An option to enable and disable Advanced Mode is available from the options menu Advanced mode allows for the display and editing of some additional details that are only required by advanced users 8 10 1 Provisioning the Device A provisioned device will be connected to the SIGMA network All devices should arrive already provisioned but this can also be completed in advanced mode if required ...

Страница 23: ...7 A QR code will be generated To copy simply right click and copy the code This code changes approximately every 15 minutes or when the code has been used To generate a new QR code at any time press F5 8 Paste the code into the Static Admin software 9 When the QR code has been pasted click on the device It should be recognisable by the known serial number 10 To check that the device is correctly p...

Страница 24: ...etium 99m Californium 252 Manganese 55 Thallium 201 Chromium 51 Molybdenum 99 Thorium 232 Cobalt 57 Neptunium 237 Tin 113 Cobalt 60 in various shielding Palladium 109 Uranium 235 Europium 152 Plutonium 239 Uranium 238 Fluorine 18 Plutonium reactor grade in various shielding Uranium depleted in various shielding Gallium 67 Plutonium weapons grade in various shielding Uranium highly enriched in vari...

Страница 25: ... backup Power consumption 9W Mounting Wall mounting screws supplied Pole mounting Universal band clamp fixture for poles up to 7 5 in diameter 194 mm Cellular 3G 4G LTE Mains Supply 115V AC 10 50 60Hz 10VA 230V AC 10 50 60Hz 10VA Product is compatible with either voltage range with no further modification needed Safety EN62368 1 EMC EN 61326 1 2013 RED EN 301 511 V12 5 1 EN 301 908 1 V11 1 1 EN 30...

Страница 26: ...keV spectroscopic 100 R h 1 Sv h at 662 keV with high dose module Neutron detector material Non 3 He Neutron detector 9 cps in a 1 neutron per cm2 field Neutron detector gamma rejection Better than 10 7 meets ANSI N42 34 section 6 7 Maximum throughput for neutron channel 5 000 cps SIGMA Network Specification Spectra storage ANSI N42 42 compliant Isotope ID Special isotope s detection Classificatio...

Страница 27: ... document or for incidental special or consequential damages related to the use of this document The information contained in this document shall be subject to change without notice 11 1 FCC Warning The D3S Static Node device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 The device may not cause harmful interference 2 The device must accept any inter...

Страница 28: ...Kromek Limited NETPark Thomas Wright Way Sedgefield County Durham TS21 3FD United Kingdom T 44 0 1740 626060 E service kromek com W www kromek com ...