2 CHeCKInG tHe UsAGe
Burner for heating industrial thermoprocessing equip-
ment. For installation in a burner block or for use with
an extended, heat-resistant burner tube. For natural
gas, town gas and LPG. Other types of gas on request.
This function is only guaranteed when used within the
specified limits – see also page 15 (10 Technical
data). Any other use is considered as non-compliant.
2.1 type label
Construction stage, rated capacity Q
max
, gas type and
diameter of gas measuring orifice (as of construction
stage E) – see type label.
Elster GmbH
Osnabrück, Made in Germany
BIO 80HB-100/35-(16)F
84021014
P 150 kW
Ø 13 mm
.3322
2.2 type code
BIo, ZIo
Burner for gas
BIoA
Burner for gas, with aluminium housing
BIoW
Burner for gas, with ceramic fibre
insulation (RCF)
50-140
Burner size
R
Cold air
K
Flat flame
H
Hot air/high furnace temperature
B
Natural gas
D
Coke oven gas, town gas
G
Propane, propane/butane, butane
M
Propane, propane/butane, butane (with
mixer)
L
Low calorific value gas
F
biogas
L
Torch
R
Reduced capacity
-X
X mm length of steel tube as of furnace
flange (L1)
/X
X mm distance from furnace flange to
front edge of burner head (L2)
-(X)
Burner head identifier
A-Z
Construction stage
B
With purge air bore holes
H
High temperature version
Z
Special version
2.3 Part designations
1
3
4
5
6
7
2
1
Burner insert
2
Type label
3
Gas housing gasket
4
Air housing
5
Burner tube set
6
Mounting gasket (not included in the delivery)
7
Operating instructions – for more documents
and calculation tools, see www.adlatus.org
2.4 Burner head
➔
Check letter marking and identification marks on
the burner head using the information provided
on the type label.
3 InstALLAtIon
3.1 Conical burner block
➔
For industrial furnaces and kilns and for burning in
an open combustion chamber.
➔
Control: High/Low, continuous.
➔
Type of burner head: R.
➔
Max. capacity: 100%.
➔
We recommend the cold air operating mode; oth-
erwise the nitric oxide values will be too high.