8 teCHnICAL DAtA

8.1 Ambient conditions

Enclosure to IEC 60529: IP 54 (IP 65).
Permitted ambient temperature in operation:  
DL..A, DL..K: -20 to +80°C (-4 to +176°F),  
DL..T: -40 to +60°C (-40 to +140°F). 
Storage and transport temperatures:  

-20 to +40°C (-4 to +104°F). 

Micro switch to EN 61058-1.
Gas types: air or flue gas, no flammable gases, no 
aggressive gases.
Icing, condensation and dew in and on the unit are 
not permitted. 
Safety class II to VDE 0106-1.

This unit is not suitable for cleaning with a high-pres-

sure cleaner and/or cleaning products. 

8.1.1 Pressure switch with nBR diaphragm

Long-term use in the upper ambient temperature range 
accelerates the ageing of the elastomer materials and 
reduces the service life (please contact manufacturer). 
Ozone concentrations exceeding 200 μg/m

3

 accel-

erate the ageing of elastomer materials and reduce 
the service life. 

8.2 Mechanical data

Medium temperature = ambient temperature.
Max. inlet pressure p

max.

 = withstand pressure, 

switching differential, see page 5 (5.1 Adjusting 
rangeDL..A, DL..K).
 
Diaphragm pressure switch, NBR, silicone-free.
Housing: glass fibre reinforced PBT plastic with low 
gas release.
Weight: DL..A: 190 g (6,7 oz), DL..K: 220 g (7,8 oz) 
Recommended tightening torque:

Component

tightening 

torque 

[ncm]

Cover screws

65

M16 x 1.5 cable gland

50

Clamping terminal screws

80

Rp 1/8 connection on upper 

housing section

250

Rp 1/4 (1/4" NPT) connection on 

lower housing section

600

8.3 electrical data

Line entrance: M16 x 1.5 (1/2" NPT conduit),  
clamping range: diameters of 4 to 10 mm.  

Type of connection: screw terminals,  

cable diameter: 0.5 to 1.8 mm (AWG 24 to 

AWG 13). 

8.3.1 switching capacity

U

I  

(cos φ = 1)

I  

(cos φ = 0.6)

DL

24–

250 V AC

0.05–5 A

0.05–1 A

DL..G

5–250 V AC

0.01–5 A

0.01–1 A

DL..G

5–48 V DC

0.01–1 A

0.01–1 A

DL..T

30–

240 V AC

5 A

0.5 A

DL..TG

< 30 V AC/

DC

0.1 A

0.05 A

Contact gap < 3 mm (μ).
If the pressure switch has switched a voltage > 24 V 
(> 30 V) and a current > 0.1 A at cos φ = 1 or 

> 0.05 A at cos φ = 0.6 once, the gold plating on 

the contacts will have been burnt through. It can 
then only be operated at this power rating or higher 
power rating. 

9 DesIGneD LIFetIMe

This information on the designed lifetime is based on 

using the product in accordance with these operat-
ing instructions. Once the designed lifetime has been 
reached, safety-relevant products must be replaced.
Designed lifetime (based on date of manufacture) in 
accordance with EN 13611, EN 1854 for DL..A, DL..K: 

10 Jahre years. 

You can find further explanations in the applicable 

rules and regulations and on the afecor website (www.
afecor.org).
 

This procedure applies to heating systems. For ther-

moprocessing equipment, observe local regulations.

Содержание DL A Series

Страница 1: ...in accordance with the regulations and standards in force These instructions can also be found at www docuthek com 1 2 Explanation of symbols 1 2 3 a b c Action Instruction 1 3 Liability We will not be held liable for damage resulting from non observance of the instructions and non com pliant use 1 4 Safety instructions Information that is relevant for safety is indicated in the instructions as fo...

Страница 2: ...re mains volt age ambient temperature enclosure see type label 3 INSTALLATION CAUTION Please observe the following to ensure that the unit is not damaged during installation Dropping the device can cause permanent damage In this event replace the entire device and associated modules before use Use approved sealing material only Condensation must not be allowed to get into the housing If possible i...

Страница 3: ...5 x 8 mm DL A Ø 3 5 x 8 mm Ø 4 x 8 mm DL 3K Ø 2 7 x 8 mm Ø 3 x 8 mm DL 3K Ø 3 5 x 8 mm Ø 4 x 8 mm DL 5 150K Ø 3 x 16 mm Ø 3 5 x 16 mm 49 5 1 9 44 5 1 7 ø 2 7 x 8 0 11 x 0 3 ø 3 5 x 8 0 14 x 0 3 ø 6 1 ø 0 24 DL A Rp DL AT NPT DL 1 5A DL 3A DL 3K 49 5 1 9 44 5 1 7 ø 2 7 x 8 ø 0 11 x 0 3 ø 3 5 x 8 ø 0 14 x 0 3 DL A Rp DL AT NPT DL 5 150A 9 5 0 4 9 5 0 4 15 5 0 6 45 1 8 54 5 2 1 6 0 2 ø 3 x 16 ø 0 11 ...

Страница 4: ...his power rating or higher power rating CAUTION To ensure that the DL is not damaged during operation note the switching capacity see page 7 8 Technical data In the case of low switching capacities such as 24 V 8 mA for example we recommend using an RC mod ule 22 Ω 1 μF in air containing silicone or oil NO C 1 µF R 22 Ω 2 NC 1 COM 3 1 Disconnect the system from the electrical power supply 2 3 4 5 ...

Страница 5: ...x DL 1 5A 0 5 1 5 50 0 1 0 16 DL 3A DL 3K 0 2 3 50 0 1 0 16 DL 3AT DL 3KT 0 3 3 150 0 1 0 16 DL 5A DL 5K 0 4 6 300 0 2 0 3 DL 5AT DL 5KT 0 5 5 300 0 2 0 3 DL 10A DL 10K DL 10AT DL 10KT 1 10 300 0 25 0 4 DL 30A DL 30K 2 5 30 300 0 35 0 9 Adjusting range1 mbar Max inlet pres sure2 mbar Mean switching differential3 mbar min max min max DL 50A DL 50K DL 50AT DL 50KT 2 5 50 300 0 8 1 5 DL 150A DL 150K ...

Страница 6: ...0430 230 V AC I 0 6 mA Order No 74920429 Pilot lamp blue 110 120 V AC I 1 2 mA Order No 74916121 230 V AC I 0 6 mA Order No 74916122 1 2 3 4 NC 1 COM 3 NO NO 2 N NO 2 NC 1 COM 3 L1 N NC 1 COM 3 NO NC 2 N NO 2 NC 1 COM 3 L1 N 7 2 Red green pilot LED for 24 V DC AC or for 110 V AC to 230 V AC 24 V DC I 16 mA 24 V AC I 8 mA Order No 74921089 110 V AC to 230 V AC Order No 74923275 1 2 3 4 NC 1 COM 3 N...

Страница 7: ...mponent Tightening torque Ncm Cover screws 65 M16 x 1 5 cable gland 50 Clamping terminal screws 80 Rp 1 8 connection on upper housing section 250 Rp 1 4 1 4 NPT connection on lower housing section 600 8 3 Electrical data Line entrance M16 x 1 5 1 2 NPT conduit clamping range diameters of 4 to 10 mm Type of connection screw terminals cable diameter 0 5 to 1 8 mm AWG 24 to AWG 13 8 3 1 Switching cap...

Страница 8: ...mage on the unit or packaging without delay Check that the delivery is complete Storage Storage temperature see page 7 8 Technical data Storage is subject to the ambient conditions described Storage time 6 months in the original packaging before using for the first time If stored for longer than this the overall service life will be reduced by the corresponding amount of extra storage time 12 DISP...

Отзывы: