![Krom Schroder DL A Series Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/krom-schroder/dl-a-series/dl-a-series_operating-instructions-manual_2004638005.webp)
DL..A, DL..K · Edition 02.22
EN-5
NO
2
NC
1
COM
3
5 ADJUstMent
➔
The switching point is adjustable via hand wheel.
1
Disconnect the system from the electrical power
supply.
2
Unscrew the housing cover.
➔
Once the settings have been adjusted successfully,
fit the housing cover again. Note the tightening
torques, see page 7 (8 Technical data).
3
Connect an ohmmeter.
COM
3
NC
1
NO
2
NO
2
NC
1
COM
3
4
Set the switching point using the hand wheel.
5
Connect a pressure gauge.
6
0
1 cm = 1 mbar
(0.4" = 0.4"WC)
7
Apply pressure. In doing so, monitor the switching
point on the ohmmeter and the pressure gauge.
8
If the DL..A, DL..K does not trip at the desired
switching point, correct the adjusting range using
the hand wheel. Relieve the pressure and repeat
the process.
5.1 Adjusting rangeDL..A, DL..K
Adjusting
range
1)
[mbar]
Max.
inlet
pres-
sure
2)
[mbar]
Mean
switching
differential
3)
[mbar]
min. max.
min. max.
DL 1,5A
-0.5
1.5
50
0.1
0.16
DL 3A,
DL 3K
0.2
3
50
0.1
0.16
DL 3AT,
DL 3KT
0.3
3
150
0.1
0.16
DL 5A,
DL 5K
0.4
6
300
0.2
0.3
DL 5AT,
DL 5KT
0.5
5
300
0.2
0.3
DL 10A,
DL 10K,
DL 10AT,
DL 10KT
1
10
300
0.25
0.4
DL 30A,
DL 30K
2.5
30
300
0.35
0.9
Adjusting
range
1)
[mbar]
Max.
inlet
pres-
sure
2)
[mbar]
Mean
switching
differential
3)
[mbar]
min. max.
min. max.
DL 50A,
DL 50K,
DL 50AT,
DL 50KT
2.5
50
300
0.8
1.5
DL 150A,
DL 150K
30
150
300
3
5
Adjusting
range
1)
["WC]
Max.
inlet
pres-
sure
2)
["WC]
Mean
switching
differential
3)
["WC]
min. max.
min. max.
DL 3AT,
DL 3KT
0.12
1.2
58.5
0.04
0.06
DL 5AT,
DL 5KT
0.2
2
117
0.08
0.12
DL 10AT,
DL 10KT
0.4
4
117
0.1
0.16
DL 50AT,
DL 50KT
1
20
117
0.3
0.6
1)
Adjusting tolerance ± 15% of the scale value, but min.
± 4 Pa [± 0.016 "WC].
2)
Max. inlet pressure = withstand pressure.
3)
Mean switching differential at min. and max. setting.
type
Deviation from the switching
point during testing pursuant
to en 1854 Air pressure
switches
DL 1,5A
± 15% or ± 6 Pa [± 0.02 "WC]
DL 3A, DL 3K
DL 3AT,
DL 3KT
± 15% or ± 6 Pa [± 0.02 "WC]
DL 5AT–
DL50AT,
DL 5KT–
50KT
± 15% or ± 4 Pa [± 0.016 "WC]
DL 5–150A,
DL 5–150K
± 15% or ± 4 Pa [± 0.016 "WC]