Local display:
back-lit LCD
Display functions
actual flow rate, forward-, reverse-
and sum-totalizers (7 digit), transi-
tion time and error messages;
each programmable for continu-
ous or sequential display
Display units
actual flow
liters, m3, or US gallons per sec-
ond, minute or hour and one free
programmable unit
totalizers
liters, m3, or US gallons and one
freely
programmable unit; min. one year
overflow time
Display language
English, French, German, Dutch;
other languages on request
Display arrangement
8 digit , 7 element numerical and
sign display,
1st line
symbols for push-button acknow-
ledgement
2nd line
10 character 14 segment text dis-
play.
3rd line
4 markers to identify the actual
display function
functions
location, actual flow rate (and
direction), totalizer, time, transit-
time and error messages
81