ELECTRICAL CONNECTIONS
4
17
OPTISENS TSS 2000
www.krohne.com
07/2018 - 4006304401 - OPTISENS TSS 2000 en R01
The following instructions describe the connection of the sensor cable.
Connecting the sensor cable to the signal converter
•
Remove the terminal cover.
•
Thread the sensor cable through one cable gland
1
.
•
Push the wires
7
into terminal J
3
, Q
4
, Y
5
, V
6
and S
2
.
•
To remove a wire, press down the white clip
8
on the corresponding terminal and pull the
wire out.
Figure 4-1: Sensor connection terminals on the signal converter MAC 100
1
Sensor connection terminal
2
Relays
3
Terminal block A: terminals for sensors
4
Terminal block S (protective earth)
Wire
Wire
Wire
Wire
Terminal block Pos.A
Terminal block Pos.A
Terminal block Pos.A
Terminal block Pos.A
Blue
J
Brown
Q
Green
Y
Yellow
V
None
W
Wire
Wire
Wire
Wire
Terminal S
Terminal S
Terminal S
Terminal S
Black (isolated cable)
S
Figure 4-2: Connecting the sensor cable