6
TECHNICAL DATA
32
OPTIFLUX 5000
www.krohne.com
03/2017 - 4000686204 - MA OPTIFLUX 5000 SW R04 en
In combination with the IFC 300
In combination with the IFC 100
In combination with the IFC 050
Accuracy
Curve
DN2.5...6 / 1/10...1/4"
0.3% of mv + 2 mm/s
3
DN10...100 / 3/8... 4"
0.15% of mv + 1 mm/s
1
Accuracy
Curve
DN2.5...6 / 1/10...1/4"
0.4% of mv + 1 mm/s
As
2
+ 0.1%
DN10...100 / 3/8...4"
0.3% of mv + 1 mm/s
2
Accuracy
Curve
DN2.5...6 / 1/10...1/4"
0.5% of mv + 1 mm/s
4
DN10...100 / 3/8...4"
0.5% of mv + 1 mm/s
INFORMATION!
Optionally, extended calibration at 2 points for optimised accuracy available for
IFC 050 and IFC 100. See for more details the relevant signal converter documentation