background image

OPTIFLUX 2070

  nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn

www.krohne.com

 

Addresses:

Germany

Northern sales office

KROHNE Messtechnik GmbH & Co. KG 
Bremer Str. 133
D-21073 Hamburg
Phone:+49 (0)40 767 3340 
Fax:+49 (0)40 767 33412 
[email protected] 
ZIP code: 10000 - 29999, 49000 - 49999 

Western and middle sales office

KROHNE Messtechnik GmbH & Co. KG
Ludwig-Krohne-Straße
D-47058 Duisburg
Phone:+49 (0)203 301 416 
Fax:+49 (0)203 301 10416 
[email protected] 
ZIP code: 30000 - 34999,  37000 - 
48000, 50000 - 53999,  57000 - 59999, 
98000 - 99999

Southern sales office

KROHNE Messtechnik GmbH & Co. KG 
Landsberger Str. 392 
D-81241 Munich 
Phone:+49 (0)89 121 5620 
Fax:+49 (0)89 129 6190 
[email protected]
ZIP code:  0 - 9999, 80000 - 89999,  
90000 - 97999 

Southwestern sales office

KROHNE Messtechnik GmbH & Co. KG 
Rüdesheimer Str. 40 
D-65239 Hochheim/Main 
Phone: +49(0)6146) 827 30 
Fax:+49 (0)6146 827 312 
[email protected] 
ZIP code: 35000 - 36999, 54000 - 
56999, 60000 - 79999

Instrumentation and control 
equipment catalog

TABLAR Messtechnik GmbH 
Ludwig-Krohne-Straße 5
D-47058 Duisburg 
Phone:+49 (0)2 03 305 880 
Fax:+49 (0)2 03 305 8888 
[email protected] www.tablar.de 

KROHNE sales 
companies

International

Australia

Australia

Australia

Australia
 KROHNE Australia Pty Ltd
Quantum Business Park 10/287
Victoria Rd Rydalmere NSW 2116 
Phone: +61 2 8846 1700 
Fax: +61 2 8846 1755 
[email protected] 

Austria

Austria

Austria

Austria
KROHNE Gesellschaft m.b.H.
Modecenterstraße 14
A-1030 Vienna
Phone:+43 (0)1/203 45 32
Fax:+43 (0)1/203 45 32 99
[email protected]

Belgium 

Belgium 

Belgium 

Belgium 
KROHNE Belgium N.V.
Brusselstraat 320 
B-1702 Groot Bijgaarden 
Phone:+32 (0)2 4 66 00 10 
Fax:+32 (0)2 4 66 08 00 
[email protected]

Brazil 

Brazil 

Brazil 

Brazil 
KROHNE Conaut Controles 
Automaticos Ltda. 
Estrada Das Águas Espraiadas, 230 
C.P. 56 06835 - 080 EMBU - SP 
Phone:+55 (0)11-4785-2700 
Fax:+55 (0)11 4785-2768 
[email protected] 

China

China

China

China
KROHNE Measurement Instruments 
(Shanghai) Co. Ltd., (KMIC)
Room 1501
1033 Zhaojiabang Road
Shanghai 200030
Phone: +86 21 6487 9611
Fax:+86 21 6438 7110
[email protected]

Czech Republic

Czech Republic

Czech Republic

Czech Republic
Krohne CZ, spol. s r.o.
Sobìsická 156
63800 Brno
Phone: +420 (0)545.242 627
Fax: +420 (0)545 220 093
[email protected]

France

France

France

France
KROHNE S.A.S.
Les Ors BP 98
F-26103 ROMANS Cedex
Phone:+33 (0)4 75 05 44 00
Fax:+33 (0)4 75 05 00 48
[email protected]

Great Britain

Great Britain

Great Britain

Great Britain
KROHNE Ltd.
Rutherford Drive 
Park Farm Industrial Estate 
Wellingborough
Northants NN8 6AE
Phone:+44 (0)19 33 408 500
Fax:+44 (0)19 33 408 501
[email protected]

CIS

CIS

CIS

CIS
Kanex KROHNE Engineering AG
Business-Centre Planeta
Office 404 ul.
Marxistskaja 3
109147 Moscow/Russia
Phone:+7 (0)095 911 7165
Fax:+7 (0)095 742 8873
[email protected]

India

India

India

India
Krohne Marshall Ltd.
 A-34/35, M.I.D.C. Industrial Area,
H-Block
Pimpri Poona 411018
Phone:+91 (0)202 744 2020
Fax:+91 (0)202 744 2020
[email protected]

Iran

Iran

Iran

Iran
KROHNE Liaison Office
North Sohrevardi Ave.  26,
Sarmad St., Apt. #9
Tehran 15539
Phone: +9821 8874 5973
Fax: +9821 8850 1268
[email protected]

Italy

Italy

Italy

Italy
KROHNE Italia Srl. 
Via V. Monti 75
I-20145 Milan
Phone:+39 02 4300 661
Fax:+39 02 4300 6666
[email protected]

Korea

Korea

Korea

Korea
KROHNE Korea
Room 508 Miwon Bldg  43
Yoido-Dong  Youngdeungpo-Ku
Seoul, Korea
Phone: 00-82-2-782-1900
Fax: 00-82-2-780-1749
[email protected]

Netherlands

Netherlands

Netherlands

Netherlands
KROHNE Nederland B.V.
Kerkeplaat 14
NL-3313 LC Dordrecht
Phone:+31 (0)78 630 6200
Fax:+31 (0)78 630 6405
Service Direct: +31 (0)78 630 6222
[email protected]

Norway

Norway

Norway

Norway
KROHNE Norway A.S. 
Ekholtveien 114
NO-1521 Moss
Phone:+47 (0)69 264 860
Fax:+47 (0)69 267 333
[email protected]

Poland

Poland

Poland

Poland
KROHNE Polska Sp.z.o.o.
ul. Stary Rynek Oliwski 8a
80-324 Gdansk
Phone: +48 (0)58 520 9211
Fax.:+48 (0)58 520 9212
[email protected]

Switzerland

Switzerland

Switzerland

Switzerland
KROHNE AG
Uferstr. 90
CH-4019 Basel
Phone:+41 (0)61 638 30 30
Fax:+41 (0)61 638 30 40
[email protected]

Singapore

Singapore

Singapore

Singapore
Tokyo Keiso - KROHNE (Singapore) 
Pte. Ltd.
14, International Business Park, 
Jurong East
Chiyoda Building, #01-01/02
Singapore 609922
Phone: (65) 6567 4548
Fax : (65) 6567 9874
[email protected]

Republic of South Africa

Republic of South Africa

Republic of South Africa

Republic of South Africa
KROHNE Pty. Ltd.
Bushbock Close
Corporate Park South
Midrand, Gauteng
P.O. Box 2069
Midrand, 1685
Tel.: +27 (0)11 314 1391
Fax: +27 (0)11 314 1681
[email protected]

Spain

Spain

Spain

Spain
I.I. KROHNE IBERIA, S.r.l.
Poligono Industrial Nilo
Calle Brasil, n

º

. 5

28806 Alcalá de Henares Madrid
Phone: +34 (0)91 883 2152
Fax: +34 (0)91 883 4854
 [email protected]

USA

USA

USA

USA
KROHNE, Inc.
7 Dearborn Road
Peabody, MA 01960
Phone: +1 (800) FLOWING
Phone: +1 (978) 535 6060 (in MA)
[email protected]

Representatives

Algeria 
Argentina
Cameroon
Canada
Chile
Columbia
Croatia
Denmark
Ecuador
Egypt
Finland
Gabon
Ghana
Greece
Hong Kong
Hungary
Indonesia
Iran
Ireland
Israel
Ivory Coast
Japan
Jordan
Kuwait
Libya
Lithuania
Malaysia
Mauritius
Mexico
Morocco
New Zealand
Peru
Portugal
Romania
Saudi Arabia
Senegal
Slovakia
Slovenia 
Sweden
Taiwan 
Thailand
Tunisia
Turkey
Venezuela
Yugoslavia

Other countries

KROHNE Messtechnik GmbH & Co. KG
Ludwig-Krohne-Str. 5
D-47058 Duisburg
Phone:+49 (0)203 301 0
Fax:+49 (0)203 301 389 
[email protected]

Electromagnetic flowmeters

Level measuring instruments

Variable area flowmeters

Pressure gauges

Mass flowmeters

Temperature measuring instruments

Ultrasonic flowmeters

Water solutions & analysis

Vortex flowmeters

Oil and gas turnkey solutions

Flow controllers

KROHNE Product Overview

© KRO

H

NE

04

/200

8

400

024

3601

Subj

ect t

o c

h

ange wit

h

ou

t noti

ce

Содержание OPTIFLUX 2070

Страница 1: ...Battery powered electromagnetic flowmeter OPTIFLUX 2070 OPTIFLUX 2070 OPTIFLUX 2070 OPTIFLUX 2070 Handbook Handbook Handbook Handbook...

Страница 2: ...tallation requirements 9 3 2 General installation notes 9 3 3 Storage 9 3 4 Transport 9 3 5 Installation requirements 10 3 5 1 Inlet and outlet 10 3 5 2 Mounting position and flange deviation 10 3 5 3...

Страница 3: ...0 5 1 1 Internal battery 21 6 Operation 22 6 1 Display and operating elements 22 6 2 Menu of IFC 070 converter 22 7 Service 26 7 1 Replacement of battery 26 8 Technical data 28 8 1 Technical data 28 8...

Страница 4: ...o some or all of the above disclaimer exclusions or limitations Any product purchased from the manufacturer is warranted in accordance with the relevant product documentation and our Terms and Conditi...

Страница 5: ...rding such warnings can result in serious health damage damage to the device itself or to parts of the operator s plant DANGER This symbol designates safety advice on handling electricity CAUTION Thes...

Страница 6: ...temperature range or incinerate the battery Do not crush puncture or open cells or disassemble battery packs Do not weld or solder to the body of the battery Do not expose contents of battery to wate...

Страница 7: ...mage to the carrier and to your local KROHNE office 2 2 Instrument description Two versions are available You received a compact version or a remote version Figure 2 1 Scope of delivery 1 OPTIFLUX 207...

Страница 8: ...2008 4000243601 2 3 Nameplate Figure 2 3 Nameplate OPTIFLUX 2070 1 Manufacturer 2 Voltage information 3 Material of wetted parts 4 Meter constant 5 Serial number 6 Device type CAUTION Check on the de...

Страница 9: ...e Allen key 4 mm Philips screwdriver Wrench for cable glands Wrench for wall mounting bracket remote version only Torque wrench for installing flowmeter in pipeline 3 2 General installation notes 3 3...

Страница 10: ...5 2 Mounting position and flange deviation Mount flowmeter either with converter aligned upwards or downwards Install flowmeter in line with the pipe axis Pipe flange faces must be parallel to each ot...

Страница 11: ...rohne com 04 2008 4000243601 3 5 3 Vibration 3 5 4 Magnetic field 3 5 5 Bends CAUTION Max permissible deviation of pipe flange faces Lmax Lmin 0 5 mm Figure 3 5 Vibration Figure 3 6 Magnetic field Fig...

Страница 12: ...3601 3 5 6 Open discharge Install meter on a lowered section of the pipe to ensure a full pipe condition through the meter 3 5 7 T section Figure 3 8 Preferable installation close to open discharge Fi...

Страница 13: ...all control valves downstream of flowmeter in order to avoid cavitation or distortion of flow profile 3 5 9 Pump Never install flowmeter at a pump suction side in order to avoid cavitation or flashing...

Страница 14: ...elines with internal coating and non conductive pipelines Grounding with grounding rings 3 Grounding rings CAUTION The grounding of the flowmeter provides a stable and accurate measurement Nominal siz...

Страница 15: ...rque given in tables before Nominal size inch Flange class lbs Bolts Max torque Nm Polypropylene Hardrubber 2 150 4 5 8 24 23 3 150 4 5 8 43 39 4 150 8 5 8 34 31 5 150 8 3 4 48 43 6 150 8 3 4 61 51 8...

Страница 16: ...7 Mounting of converter 3 7 1 Mounting of IFC 070 F Mount IFC 070 F with mounting plate on wall or standpipe Keep distance between sensor and signal converter as short as possible Observe length of t...

Страница 17: ...fety instructions 4 2 Terminal assignment of IFC 070 WARNING Observe the regional occupational health and safety regulations without fail Only work on the device electrics if you are appropriately tra...

Страница 18: ...5 24 VDC P 100 mW Status output passive Status output passive Status output passive Status output passive I 10 mA U 5 24 VDC P 100 mW 4 3 Signal cable Figure 4 2 Terminal assignment 1 Status output 1...

Страница 19: ...clamp the brown cable to terminal 7 and the white to terminal 8 Connect the shield to terminal 1 the purple cable to terminal 2 and the blue to terminal 3 Figure 4 3 Cable connection at flow sensor si...

Страница 20: ...to terminal 7 and the white to terminal 8 Connect the shield to terminal 1 the purple cable to terminal 2 and the blue to terminal 3 Figure 4 4 Cable connection at converter side 1 cable length 16 cm...

Страница 21: ...the battery connector to the internal connector in the IFC 070 converter check that the display lights up replace the cover tighten the 4 Allen bolts replace the blue protection cap CAUTION Please con...

Страница 22: ...o enter the value i the value flashes use the Z and V key to change the value hold the Z key for 3 seconds to confirm the new value to leave the programming mode hold the V key for 3 seconds to store...

Страница 23: ...gether with the reset button for 6 seconds as shown in the graph below Use a small screwdriver for the reset button Display starts with the menu beginning with menu no 12 Go to menu no 13 and change 1...

Страница 24: ...flow cut off 20 0 5 10 20 mm s Below value no measurement 28 Time constant flow reading 2 1 fast 2 normal 3 slow Timeconstant of display 29 Factory calibration comm mode 0 0 No 1 Yes For factory use...

Страница 25: ...ters reset 88888 Set to 00000 After reset display value is back to 88888 Confirm with for 3 seconds 71 Counters Run Stop 1 0 stop 1 run 72 All Errors Reset 0 Set to 1 After reset display value is back...

Страница 26: ...e cover Disconnect the connector of the battery Remove the battery holder by pulling it upwards Remove the battery from the holder Insert the new battery in the holder Replace the holder Fasten the ba...

Страница 27: ...hrough the available positions with the V key to position 74 and check the battery capacity important for battery life indication Go to position 75 and enter 1 reset battery counter i Battery capacity...

Страница 28: ...ange 0 12m s 0 39ft s Max deviation under reference conditions 1 0 5 of measured flowrate value 2mm s Repeatibility 0 3 v 0 5 m s 1 5 ft s Process conditions Potable water Surface water clean ground w...

Страница 29: ...less steel 1 4571 AISI 316 Ti Titanium Grounding rings Hastelloy C4 Stainless steel 1 4571 AISI 316 Ti Titanium Flanges Steel 1 0460 C 22 8 Steel 1 0038 RSt37 2 Stainless steel 1 4404 AISI 316 L Stain...

Страница 30: ...Y vs flow velocity X m s Nominal diameter VN14 VN15 ASME inch 2 2 1 2 3 4 5 6 8 10 12 14 16 18 20 24 DN mm 50 65 80 100 125 150 200 250 300 350 400 450 500 600 Versions Compact Separate Electrical con...

Страница 31: ...20 x 1 5 Optional 1 2 NPT PF 1 2 Materials Converter housing Die cast aluminium polyurethane coated In and output Outputs 2 passive pulse outputs for remote totalising f 500 Hz I 10 mA U 5 24 VDC P 10...

Страница 32: ...1 Separate flow sensor OPTIFLUX 2000 F 5 90 40 65 Compact with IFC 070 OPTIFLUX 2070 C 5 90 40 65 1 Polypropylene available for DN 50 150 Process F Ambient F min max min max Hardrubber Separate flow s...

Страница 33: ...TECHNICAL DATA 8 33 OPTIFLUX 2070 www krohne com 04 2008 4000243601 8 2 Dimensions and Weights OPTIFLUX 2070 C OPTIFLUX 2000 F IFC 070 F T W H 070 W Tbox c a 175mm 310mm 335mm...

Страница 34: ...10 600 568 565 646 738 103 450 10 600 618 615 696 788 113 500 10 600 671 670 749 841 132 600 10 600 781 780 859 951 167 Flanges acc ASME B16 5 Dimensions for 150 lbs flanges inch Approx weight lbs DN...

Страница 35: ...150 200 179 152 257 349 15 3 150 200 204 190 5 282 374 19 4 150 250 241 228 6 319 411 25 5 150 250 268 254 346 438 29 6 150 300 297 279 4 375 467 36 8 150 350 362 342 9 440 532 45 10 150 400 414 406 4...

Страница 36: ...dia India India India Krohne Marshall Ltd A 34 35 M I D C Industrial Area H Block Pimpri Poona 411018 Phone 91 0 202 744 2020 Fax 91 0 202 744 2020 pcu vsnl net Iran Iran Iran Iran KROHNE Liaison Offi...

Отзывы: