2.6.6  Magnetic field

2.6.7  Bends

Figure 2-8: Avoid magnetic fields

Figure 2-9: Installation in bending pipes

Figure 2-10: Installation in bending pipes

Содержание OPTIFLUX 1000

Страница 1: ...00 OPTIFLUX 1000 OPTIFLUX 1000 OPTIFLUX 1000 Quick Start Quick Start Quick Start Quick Start KROHNE 10 2011 7309832300 QS OPTIFLUX 1000 R03 en The documentation is only complete when used in combinati...

Страница 2: ...g position 7 2 6 3 Flange deviation 8 2 6 4 T section 8 2 6 5 Vibration 8 2 6 6 Magnetic field 9 2 6 7 Bends 9 2 6 8 Open discharge 10 2 6 9 Control valve 10 2 6 10 Air venting 10 2 6 11 Pump 11 2 6 1...

Страница 3: ...ons can result in damage to the device or to parts of the operator s plant INFORMATION These instructions contain important information for the handling of the device CAUTION Installation assembly sta...

Страница 4: ...office of the manufacturer INFORMATION The device will arrive in two cartons One carton contains the converter and one carton contains the sensor Figure 2 1 Scope of delivery 1 Ordered flowmeter 2 Pr...

Страница 5: ...on electrical connection to the measuring sensor via field current and signal cable 2 3 Nameplates 1 Remote version 2 Compact version with IFC 300 signal converter 3 Compact version with IFC 100 0 sig...

Страница 6: ...1 7309832300 QS OPTIFLUX 1000 R03 en 2 4 Storage Store the device in a dry and dust free location Avoid lasting direct exposure to the sun Store the device in its original packing Storage temperature...

Страница 7: ...UX 1000 www krohne com 10 2011 7309832300 QS OPTIFLUX 1000 R03 en 2 6 Installation conditions 2 6 1 Inlet and outlet 2 6 2 Mounting position Figure 2 3 Recommended inlet and outlet 1 5 DN 2 2 DN Figur...

Страница 8: ...OPTIFLUX 1000 R03 en 2 6 3 Flange deviation 2 6 4 T section 2 6 5 Vibration CAUTION Max permissible deviation of pipe flange faces Lmax Lmin 0 5 mm 0 02 Figure 2 5 Flange deviation 1 Lmax 2 Lmin Figur...

Страница 9: ...TIFLUX 1000 www krohne com 10 2011 7309832300 QS OPTIFLUX 1000 R03 en 2 6 6 Magnetic field 2 6 7 Bends Figure 2 8 Avoid magnetic fields Figure 2 9 Installation in bending pipes Figure 2 10 Installatio...

Страница 10: ...2011 7309832300 QS OPTIFLUX 1000 R03 en 2 6 8 Open discharge 2 6 9 Control valve 2 6 10 Air venting Figure 2 11 Installation before an open discharge Figure 2 12 Installation before control valve Figu...

Страница 11: ...ures Figure 2 14 Installation after pump CAUTION Protect the device from direct sunlight Temperature range Process C Ambient C Process F Ambient F min max min max min max min max Separate flow sensor...

Страница 12: ...ure rating bar Max torque Nm Flange size Pressure rating DN10 DN15 PN 16 40 16 16 DN15 DN15 PN 16 40 16 16 DN25 DN25 PN 16 40 16 16 DN40 DN40 PN 16 40 16 25 DN50 DN50 PN 16 40 16 45 DN80 DN80 PN 16 40...

Страница 13: ...ational health and safety regulations Any work done on the electrical components of the measuring device may only be carried out by properly trained specialists INFORMATION Look at the device nameplat...

Страница 14: ...n 3 3 Virtual reference for IFC 300 C W and F version Possible if DN10 Electrical conductivity 200 S cm Electrode cable max 50 m 164 ft type DS 3 4 Connection diagrams Figure 3 3 Virtual reference INF...

Страница 15: ...U is generated U v k B D U v k B D U v k B D U v k B D in which v mean flow velocity k factor correcting for geometry B magnetic field strength D inner diameter of flow meter The signal voltage U is...

Страница 16: ...h IFC 100 0 IFC 100 0 IFC 100 0 IFC 100 0 a 82 mm 3 2 b 161 mm 6 3 c 257 mm 10 1 1 Total height H a Compact version with Compact version with Compact version with Compact version with IFC 100 45 IFC 1...

Страница 17: ...40 150 180 130 5 7 100 16 200 207 156 10 5 150 16 200 271 219 15 0 Nominal size Dimensions inches Approx weight lb ASME PN psi L H W 3 8 580 2 68 5 39 1 85 3 7 580 2 68 5 39 1 85 3 7 1 580 2 13 5 79 2...