INSTALLATION
2
11
MS15 - MS40 SERIES
www.krohne.com
06/2020 - 4007717401 - AD ATEX MS15-MS40 R01 en
Stainless steel housing
Maximum limits for measuring chamber with EPL Ga/Gb
Maximum limits for measuring chamber with EPL Gb
Temperature
class
Maximum process
temperature
Maximum ambient temperature
Without insulation
With insulation
[
°
C]
T6
+68
+70 (+62)
T5
+80
+80 (+77)
T4
+108
+80
T3
+160
+80
T2
+180
+80
+210
+80
+74
+240
+80
+62
T1
+300
+74
Not applicable
+360
+61
Not applicable
Temperature
class
Maximum process
temperature
Maximum ambient temperature
Without insulation
With insulation
[
°
C]
T6
+80
+70 (+62)
T5
+95
+80 (+77)
T4
+130
+80
T3
+195
+80
T2
+210
+80
+74
+250
+80
+57
+290
+76
+41
T1
+300
+74
Not applicable
+350
+63
Not applicable
+400
+52
Not applicable