Warnings and symbols used

HANDLING

•  

This symbol designates all instructions for actions to be carried out by the operator in the 

specified sequence.

i

RESULT

RESULT

RESULT

RESULT
This symbol refers to all important consequences of the previous actions.

Safety instructions for the operator

DANGER!

This information refers to the immediate danger when working with electricity.

DANGER!

These warnings must be observed without fail. Even partial disregard of this warning can lead to 
serious health problems and even death. There is also the risk of seriously damaging the device 
or parts of the operator's plant.

WARNING!

Disregarding this safety warning, even if only in part, poses the risk of serious health problems. 
There is also the risk of damaging the device or parts of the operator's plant.

CAUTION!

Disregarding these instructions can result in damage to the device or to parts of the operator's 
plant.

INFORMATION!

These instructions contain important information for the handling of the device.

CAUTION!

Installation, assembly, start-up and maintenance may only be performed by appropriately 
trained personnel. The regional occupational health and safety directives must always be 
observed.

LEGAL NOTICE!

The responsibility as to the suitability and intended use of this device rests solely with the user. 
The supplier assumes no responsibility in the event of improper use by the customer. Improper 
installation and operation may lead to loss of warranty. In addition, the "Terms and Conditions of 
Sale" apply which form the basis of the purchase contract.

INFORMATION!

Further information can be found in the manual, on the data sheet, in special manuals, 
certificates and on the manufacturer's website.

If you need to return the device to the manufacturer or supplier, please fill out the form 
contained in the manual and send it with the device. Unfortunately, the manufacturer cannot 
repair or inspect the device without the completed form.

Содержание BATCHFLUX 3100

Страница 1: ...tic flowmeter for volumetric filling machines BATCHFLUX 3100 C BATCHFLUX 3100 C BATCHFLUX 3100 C BATCHFLUX 3100 C Quick Start Quick Start Quick Start Quick Start KROHNE 09 2020 4008472601 QS BATCHFLUX...

Страница 2: ...tlet 8 2 7 2 Bends in 2 or 3 dimensions 9 2 7 3 T section 9 2 7 4 Open feed or discharge 9 2 7 5 Pump 10 2 7 6 Control valve 10 2 7 7 Flange deviation 11 2 7 8 Mounting 12 2 7 9 Installation location...

Страница 3: ...ese instructions can result in damage to the device or to parts of the operator s plant INFORMATION These instructions contain important information for the handling of the device CAUTION Installation...

Страница 4: ...e that you have all the elements given in the order INFORMATION Look at the device nameplate to ensure that the device is delivered according to your order Check for the correct supply voltage printed...

Страница 5: ...ensive product specification is available using PICK the Product Information Center KROHNE web tool PICK can be found via the service menu button on the KROHNE com website Figure 2 2 Device version 2...

Страница 6: ...ng flowmeter in pipeline Always tighten the bolts uniformely and in diagonally opposite sequence Accessories necessary for the correct installation are available on request at the manufacturer Make su...

Страница 7: ...ure a reliable installation Make sure that there is adequate space to the sides Protect the signal converter from direct sunlight and install a sun shade if necessary Support the pipeline on both side...

Страница 8: ...n CAUTION Install in a slightly descending pipe section to prevent air from collecting and to avoid faulty measurements meter can drain INFORMATION Support the pipeline on both side of the flowmeter M...

Страница 9: ...ends upstream of the flowmeter 1 2 dimensions X Y 2 3 dimensions X Y Z Inlet length using bends in 2 dimensions t 5 DN when having bends in 3 dimensions t 10 DN INFORMATION 2 dimensional bends occur i...

Страница 10: ...com 09 2020 4008472601 QS BATCHFLUX 3100 R01 en 2 7 5 Pump D 25 1 Drain valve to empty pipeline 2 7 6 Control valve D 25 1 Drain valve to empty pipeline Figure 2 11 Installation behind a pump Figure...

Страница 11: ...7 7 Flange deviation Figure 2 13 Mounting position and flange deviation 1 Lmax 2 Lmin CAUTION Max permissible deviation of pipe flange faces Lmax Lmin d 0 5 mm 0 02 CAUTION Install the device always...

Страница 12: ...2 14 Horizontal installation CAUTION Mount the flow sensor in such a way that the electrode axis X X is approximately in a horizontal pipe run Figure 2 15 No force on device after installing 1 After i...

Страница 13: ...pipeline Figure 2 16 Installation in bending pipes CAUTION Install in a slightly descending pipe section of 25 degrees or larger to prevent air from collecting and to avoid faulty measurements meter...

Страница 14: ...olts uniformly and in diagonally opposite sequence Do not exceed the maximum torque value Step 1 Apply approx 50 of max torque given in table Step 2 Apply approx 80 of max torque given in table Step 3...

Страница 15: ...3 Temperatures Process temperature vs ambient temperature 1 Ambient temperature 2 Process temperature 3 Temperature area for continuous process 4 Temperature area for cleaning up to 1 hour INFORMATION...

Страница 16: ...ny work done on the electrical components of the measuring device may only be carried out by properly trained specialists INFORMATION Look at the device nameplate to ensure that the device is delivere...

Страница 17: ...nd any other electrical device at the same conductor CAUTION When connecting to functional extra low voltages 24VDC ensure that you use protective separation PELV according to IEC 60364 IEC 61140 or V...

Страница 18: ...types to connect the flowmeter to a third party system moulded plug straight or angle entry form integrally extruded plug with cable in various lengths moulded plug straight form especially suitable f...

Страница 19: ...1 M12 5 pins connector Grounding 2 Grounding strip R radius mounting hole 4 3 mm 0 17 inch DN15 version with spacer bush 1 M12 5 pins connector Grounding 2 Grounding strip R radius mounting hole 3 1...

Страница 20: ...g drawing to ensure that the device works correctly Dimensions Figure 4 1 Flange according DIN 11850 row 2 DIN 11866 row EN 10357 Serie A Figure 4 2 Flange according DIN 11850 row 2 DIN 11866 row EN 1...

Страница 21: ...NOTES 5 21 BATCHFLUX 3100 C www krohne com 09 2020 4008472601 QS BATCHFLUX 3100 R01 en...

Страница 22: ...5 NOTES 22 BATCHFLUX 3100 C www krohne com 09 2020 4008472601 QS BATCHFLUX 3100 R01 en...

Страница 23: ...NOTES 5 23 BATCHFLUX 3100 C www krohne com 09 2020 4008472601 QS BATCHFLUX 3100 R01 en...

Страница 24: ...g solutions Engineering commissioning calibration maintenance and training services Head Office KROHNE Messtechnik GmbH Ludwig Krohne Str 5 47058 Duisburg Germany Tel 49 203 301 0 Fax 49 203 301 10389...

Отзывы: