2.7.12 Torques and pressures
The maximum pressure and torques values for the flowmeter are theoretical and calculated for
optimum conditions and use with steel counter flanges.
Tightening of bolts
•
Always tighten the bolts uniformly and in diagonally opposite sequence.
•
Do not exceed the maximum torque value.
•
Step 1: Apply approx. 50% of max. torque given in table.
•
Step 2: Apply approx. 80% of max. torque given in table.
•
Step 3: Apply 100% of max. torque given in table.
Figure 2-17: Tightening of bolts
Nominal
size
Counter flanges
Max.
operating
pressure
Bolts
Bush /
spacer
Max. torque
[Nm]
Flange
size
Flange
class
DN15
15 [mm]
PN16
d
8 [bar]
4 x M8
solid spacer
22
4 x M6
open bush
9
½
"
½
[inch]
150 [lb]
d
116 [psi]
4 x M8
solid spacer
22
4 x M6
open bush
9