![KROHNE BATCHFLUX 3100 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/krohne/batchflux-3100/batchflux-3100_quick-start-manual_2004194013.webp)
INSTALLATION
2
13
BATCHFLUX 3100 C
www.krohne.com
09/2020 - 4008472601 - QS BATCHFLUX 3100 - R01 en
2.7.11 Mounting position
The flowmeter can be installed in every position.
D
> 25
°
1
Drain valve (to empty pipeline)
Figure 2-16: Installation in bending pipes
CAUTION!
Install in a slightly descending pipe section (of 25 degrees or larger), to prevent air from
collecting and to avoid faulty measurements (meter can drain).
CAUTION!
To ensure a correct measurement, avoid draining or partial filling of the flow sensor during
operation.
INFORMATION!
Vertical down position only in conjunction with a control valve.