KROHNE BATCHFLUX 3100 Скачать руководство пользователя страница 1

Electromagnetic flowmeter for volumetric filling 
machines

BATCHFLUX 3100 C

BATCHFLUX 3100 C

BATCHFLUX 3100 C

BATCHFLUX 3100 C

Quick Start

Quick Start

Quick Start

Quick Start

© KROHNE 09/2020 - 4008472601 - QS BATCHFLUX 3100 - R01 en

Содержание BATCHFLUX 3100

Страница 1: ...tic flowmeter for volumetric filling machines BATCHFLUX 3100 C BATCHFLUX 3100 C BATCHFLUX 3100 C BATCHFLUX 3100 C Quick Start Quick Start Quick Start Quick Start KROHNE 09 2020 4008472601 QS BATCHFLUX...

Страница 2: ...tlet 8 2 7 2 Bends in 2 or 3 dimensions 9 2 7 3 T section 9 2 7 4 Open feed or discharge 9 2 7 5 Pump 10 2 7 6 Control valve 10 2 7 7 Flange deviation 11 2 7 8 Mounting 12 2 7 9 Installation location...

Страница 3: ...ese instructions can result in damage to the device or to parts of the operator s plant INFORMATION These instructions contain important information for the handling of the device CAUTION Installation...

Страница 4: ...e that you have all the elements given in the order INFORMATION Look at the device nameplate to ensure that the device is delivered according to your order Check for the correct supply voltage printed...

Страница 5: ...ensive product specification is available using PICK the Product Information Center KROHNE web tool PICK can be found via the service menu button on the KROHNE com website Figure 2 2 Device version 2...

Страница 6: ...ng flowmeter in pipeline Always tighten the bolts uniformely and in diagonally opposite sequence Accessories necessary for the correct installation are available on request at the manufacturer Make su...

Страница 7: ...ure a reliable installation Make sure that there is adequate space to the sides Protect the signal converter from direct sunlight and install a sun shade if necessary Support the pipeline on both side...

Страница 8: ...n CAUTION Install in a slightly descending pipe section to prevent air from collecting and to avoid faulty measurements meter can drain INFORMATION Support the pipeline on both side of the flowmeter M...

Страница 9: ...ends upstream of the flowmeter 1 2 dimensions X Y 2 3 dimensions X Y Z Inlet length using bends in 2 dimensions t 5 DN when having bends in 3 dimensions t 10 DN INFORMATION 2 dimensional bends occur i...

Страница 10: ...com 09 2020 4008472601 QS BATCHFLUX 3100 R01 en 2 7 5 Pump D 25 1 Drain valve to empty pipeline 2 7 6 Control valve D 25 1 Drain valve to empty pipeline Figure 2 11 Installation behind a pump Figure...

Страница 11: ...7 7 Flange deviation Figure 2 13 Mounting position and flange deviation 1 Lmax 2 Lmin CAUTION Max permissible deviation of pipe flange faces Lmax Lmin d 0 5 mm 0 02 CAUTION Install the device always...

Страница 12: ...2 14 Horizontal installation CAUTION Mount the flow sensor in such a way that the electrode axis X X is approximately in a horizontal pipe run Figure 2 15 No force on device after installing 1 After i...

Страница 13: ...pipeline Figure 2 16 Installation in bending pipes CAUTION Install in a slightly descending pipe section of 25 degrees or larger to prevent air from collecting and to avoid faulty measurements meter...

Страница 14: ...olts uniformly and in diagonally opposite sequence Do not exceed the maximum torque value Step 1 Apply approx 50 of max torque given in table Step 2 Apply approx 80 of max torque given in table Step 3...

Страница 15: ...3 Temperatures Process temperature vs ambient temperature 1 Ambient temperature 2 Process temperature 3 Temperature area for continuous process 4 Temperature area for cleaning up to 1 hour INFORMATION...

Страница 16: ...ny work done on the electrical components of the measuring device may only be carried out by properly trained specialists INFORMATION Look at the device nameplate to ensure that the device is delivere...

Страница 17: ...nd any other electrical device at the same conductor CAUTION When connecting to functional extra low voltages 24VDC ensure that you use protective separation PELV according to IEC 60364 IEC 61140 or V...

Страница 18: ...types to connect the flowmeter to a third party system moulded plug straight or angle entry form integrally extruded plug with cable in various lengths moulded plug straight form especially suitable f...

Страница 19: ...1 M12 5 pins connector Grounding 2 Grounding strip R radius mounting hole 4 3 mm 0 17 inch DN15 version with spacer bush 1 M12 5 pins connector Grounding 2 Grounding strip R radius mounting hole 3 1...

Страница 20: ...g drawing to ensure that the device works correctly Dimensions Figure 4 1 Flange according DIN 11850 row 2 DIN 11866 row EN 10357 Serie A Figure 4 2 Flange according DIN 11850 row 2 DIN 11866 row EN 1...

Страница 21: ...NOTES 5 21 BATCHFLUX 3100 C www krohne com 09 2020 4008472601 QS BATCHFLUX 3100 R01 en...

Страница 22: ...5 NOTES 22 BATCHFLUX 3100 C www krohne com 09 2020 4008472601 QS BATCHFLUX 3100 R01 en...

Страница 23: ...NOTES 5 23 BATCHFLUX 3100 C www krohne com 09 2020 4008472601 QS BATCHFLUX 3100 R01 en...

Страница 24: ...g solutions Engineering commissioning calibration maintenance and training services Head Office KROHNE Messtechnik GmbH Ludwig Krohne Str 5 47058 Duisburg Germany Tel 49 203 301 0 Fax 49 203 301 10389...