ALTERNATING CURRENT (AC) CONNECTION
Be sure any electric devices are turned off before
plugging them in.
Be sure all electric devices including the lines and
plug connections are in good condition before
connection to the generator. Be sure the total load is
within generator rated output. Be sure the receptacle
load current is within receptacle rated current.
TIP:
Make sure to ground (Earth) the generator. When the
electric device is earthed, always the generator must
be earthed.
TIP:
1. Start the engine.
2. Turn the ESC to “ON”.
3. Plug in to AC receptacle.
4. Make sure the AC pilot light is on.
5. Turn on any electrical device
TIP:
The ESC must be turned to “OFF” before increasing
engine speed to rated rpm.
- Most motorized appliances require more than their
electrical rating for startup. When an electrical
motor is started, the overload indicator (red) may
come on. This is normal if the overload indicator
(red) goes off within 4 seconds. If the overload
indicator (red) stays on, consult your generator
dealer.
- If the generator is connected to multiple loads or
electricity consumers, please remember to first
connect the one with the highest starting current.
And last connect the one with the lowest starting
current.
- If the generator is overload, or if there is a short
circuit in a connected appliance, the overload
indicator (red) will go ON. The overload indicator
(red) will stay ON, and after about 4 seconds,
current to the connected appliance(s) will shut
off, and the output indicator (green) will go OFF.
Stop both engines and investigate the problem.
Determine if the cause is a short circuit in a
connected appliance or an overload, correct the
problem and restart the generator.
BATTERY CHARGING
- The generator DC rated voltage is 12V.
- Start the engine first, and then connect the
generator to the battery for charging.
- Before starting to charge the battery, make sure
that the DC protector is turned on.
1. Start the engine.
2. Connect the red battery charger lead to the
positive (+) battery terminal.
3. Connect the black battery charger lead to the
negative (-) battery terminal.
4. Turn the ESC “OFF” to start battery charging.
• Be sure the ESC is turned off while charging the
battery.
• Be sure to connect the red battery charger lead to
the positive (+) battery terminal, and connect the
black lead to the negative (-) battery terminal. Do
not reverse these positions.
• Connect the battery charger leads to the
battery terminals securely so that they are not
disconnected due to engine vibration or other
disturbances.
• Charge the battery in the correct procedure by
following instructions in the owner’s manual for
the battery.
• The DC protector turns off automatically if current
above the rated flows during battery haring. To
restart charging the battery, turn he DC protector
on by pressing its button to “ON”. If the DC
protector turns off again, top charging
TIP:
• Follow instructions in the owner are manual for the
battery to determine the end of battery charging.
• Measure the specific gravity of electrolyte to
determine if the battery is fully charged. At full
charge, the electrolyte specific gravity is between
1.26 and 1.28.
• It is advisable to check the specific gravity of the
electrolyte at least once every hour to prevent
overcharging the battery.
When charging a car battery, do not start the car
engine while the charging cables are connected
and the power supply is running. This can cause
damage to both the car electrical system and power
supply.
Never smoke or make and break connections at
the battery while charging. Sparks may ignite the
battery gas. Battery electrolyte is poisonous and
dangerous, causing severe burns, etc. contains
sulfuric (sulphuric) acid. Avoid contact with skin,
eyes or clothing.
IMMEDIATE ACTIONS IF IN CONTACT WITH
BATTERY ACID:
External - Flush with water.
Internal - Drink large amount of water and contact
hospital immediately.
Eyes - Flush with water for 15 minutes and get
prompt medical attention.
Batteries produce explosive gases. Keep sparks,
flame, cigarettes, etc., away. Ventilate when charging
or using in closed space. Always cover eyes when
working near batteries.
KEEP OUT OF REACH OF CHILDREN
APPLICATION RANGE
When using the generator, make sure the total load
is within rated output of a generator. Otherwise,
generator damage may occur.
AC
Power
factor
2000i
1
~3000W
0,8 - 0,95
~2400W
0,4 - 0,75
(efficiency
0,85)
~1200W
DC
Rated voltage 12V
Rayted current 8,3A
TIP:
Application wattage indicates when each device is
used by itself. The simultaneous usage of AC and
DC power is possible but total wattage should not
exceed the rated output.
Generator rated output
3000VA
Frequency
Power factor
AC
1,0
~3000W
0,8
~2400W
DC
- -
100W
(12V/8,3A)