In case of failed operation:
U>
a: AC over voltage, indicating the character of AC
(alternative indication of AC and digit).
b: DC over voltage, indicating the character of DC
(alternative indication of DC and digit).
U<
a: AC under-voltage, indicating the character of AC
(alternative indication of AC and digit).
b: DC under-voltage, indicating the character of DC
(alternative indication of DC and digit).
I> Output power by generator
Output short cicuit of generator
Over heat of generator
Maintenance time
OIL WARNING LIGHT
When the oil level falls below the lower level, the
oil warning light comes on and the engine stops
automatically. Unless you refill with oil, the engine
will not start again.
TIP: If the engine stalls or does not start, turn the
engine switch to “ON” and then pull the recoil starter.
If the oil warning light flickers for a few seconds, the
engine oil is insufficient. Add oil and restart.
OVERLOAD INDICATOR LIGHT (RED)
The overload indicator light (1) comes on when an
overload of a connected electrical device is detected,
the inverter control unit overheats, or the AC output
voltage rises. Then, the AC protector will trip,
stopping power generation in order to protect the
generator and any connected electric devices. The
AC pilot light (Green) will go off and the overload
indicator light (Red) will stay on, but the engine will
not stop running.
When the overload indicator light comes on and
power generation stops, proceed as follows:
1. Turn off any connected electric devices and stop
the engine.
2. Reduce the total wattage of connected electric
devices within the rated output.
3. Check if there are any ventilation blockage, in case
remove blockage.
4. When above instructions are completed, please
restart engine.
TIP: The overload warning light may light and light
for a few seconds when used electrical equipment
requiring high starting current. Examples of this
may be submersible lens pumps and chainsaws.
This is consequently no indication that an error has
occurred.
AC PILOT LIGHT (GREEN)
The AC pilot light (1) comes on when the
engine starts and produces power.
DC PROTECTOR 12V
The DC protector turns to “OFF” automatically when
electric device being connected to the generator
is operating and current above the rated flows. To
use this equipment again, turn on DC protector by
pressing
1. “ON” – DC 12V is on
2. “OFF” – DC 12V is off.
Reduce the load of the connected electric device
below the specified rated output of the generator if
the DC protector turns off. If the DC protector turns
off again, stop using the device immediately and
consult a franchised dealer.
ENGINE SMART CONTROL (ESC)
1. “ON” When the ESC switch is turned to “ON”, the
economy control unit controls the engine speed
according to the connected load. The results are
better fuel consumption and less
2. When the ESC switch is turned to “OFF”, the
engine runs at the rated (5000r/min) Regard-less
of whether is load connected or not.
Tip: The ESC must not be turned to “OFF” when
using electric devices that require a large starting
current, such as a compressor of a submergible
pump.