18 English
Operation
SaebelS-EN / 0809
EN
Noise levels
Measured values determined according to
EN 60 745.
The average A-weighted noise level of the tool is:
Sound pressure level (L
pA
)
90 dB(A)
Sound power level (L
wA
)
101 dB(A)
Measurement uncertainty K = 3 dB
Vibration
Triaxial vibration emission value, measured in ac-
cordance with EN 60745.
Sabre saw
1200 SPE
The vibration emission level will vary because of
the ways in which a power tool can be used and
may increase above the level given in this infor-
mation sheet. This could lead to underestimation
of vibration when the tool is used regularly in such
a manner.
Note:
To be accurate, an estimation of the level of
exposure to vibration experienced during a given
period of work should also take into account the
times when the tool is switched off and when it is
running but not actually when doing the job.
4. Operation
Before putting into operation, check that the mains
voltage and frequency on the identification plate
match the details of your mains supply.
Fixed power supply
Damaged mains cables must not be used. They
must be replaced immediately by an expert tech-
nician.
Switching on and off
Press or release
1
the On/Off switch.
Changing the cutting rate
The cutting rate of the power tool when it is
switched on is infinitely variable, depending on
how far you press in the On/Off switch
1
.
Noise/vibration information
The noise level can exceed 85 dB(A)
during operation.
Wear ear protection!
Sawing wood; a
h
:
m/s² 24.6
Measurement uncertainty K
m/s²
10.9
The vibration emission level given in
this information sheet has been
measured in accordance with a
standardised test given in EN 60745
and may be used to compare one
tool with another.
This may significantly reduce the exposure level
over the total working period.
Before carrying out any work on the
machine, pull the mains plug.
Putting into operation
Observe correct main voltage!
If using an extension cable: Only use
extension cables specifically
approved for the application with the
required cross-section. Otherwise the
power of the tool can be reduced and
the cable can overheat. Replace
damaged cables.
Mains cable
If the mains cable is damaged while
working, pull the mains plug immedi-
ately.
Fixed power supply
Operation
37995_BA_Saebelsaege.book Seite 18 Donnerstag, 30. Oktober 2008 3:06 15
Содержание 1200 SPE
Страница 2: ...SPE DE 0809 E F min 40 mm min 40 mm ...
Страница 3: ...SPE DE 0809 A B C D 5 8 4 7 6 3 2 1 9 8 4 7 5 6 3 ...
Страница 191: ...Notizen Notes 191 Notizen 0810 ...
Страница 192: ...192 Notizen Notes Notizen 0810 ...
Страница 193: ...Notizen Notes 193 Notizen 0810 ...