Operation
English 17
FME-EN / 0904
EN
Noise levels
Measurement values determined according to EN
60 745.
The A-weighted noise level of the device is typical-
ly:
Sound pressure level (L
pA
)
78 dB(A)
Sound power level (L
wA
)
89 dB(A)
Measurement uncertainty K = 3 dB
4. Operation
Before putting into operation, check that the mains
voltage and frequency on the identification plate
match the details of your mains supply.
Connect mains cable module if necessary
Fixed power supply
Damaged mains cables must not be used. They
must be replaced immediately by an expert tech-
nician.
Mains cable module
Connect the mains cable module
7
to the handle.
The plug must snap in.
Use the mains cable module
7
only for Kress elec-
tric tools. Do not attempt to operate other ma-
chines with the module.
Damaged mains cable modules must not be used.
They must be replaced by a new Kress mains ca-
ble module immediately.
Push the two unlocking buttons
4
and remove the
mains cable module
7
from the handle.
Use only an original Kress mains cable module.
Continuous electronic control
(Option)
Electronic control
(Option)
Soft starter
The starting current limitation reduces the starting
current. The motor revs up slowly until it reaches
the preselected rotational speed. This can extend
the service life of the machine.
Electronic overload protection
With a load that is too high, which therefore im-
plies a risk to the motor, the rotational speed of the
milling motor is reduced by the integrated monitor-
ing of the motor. The machine must be released
(preferably remove it a short distance from the
workpiece) to ensure that you can have full capac-
ity again.
Your power tool is doubly insulated in
compliance with EN 60745; there is
thus no need for an earth wire.
The machine is radio and TV interference-free in
accordance with EN 55014-1 and interference-
proof in accordance with EN 55014-2.
Noise and Vibration Information
The noise level can exceed 85 dB(A)
during operation.
Wear ear protection!
Before carrying out any work on the
machine, pull the mains plug.
Putting into operation
Observe correct main voltage!
Mains Cable
If the mains cable is damaged while
working, pull the mains plug immedi-
ately.
Fixed power supply
Mains cable module with Patent
Quick Interlock.
Additional function
The continuous electronic control
keeps the speed almost constant
under no-load and under load and
ensures uniform performance.
In the event of overload or overheat-
ing during continuous operation, the
speed is automatically reduced until
the machine has cooled sufficiently.
35664_BA_FME_0904.book Seite 17 Montag, 18. Mai 2009 10:09 10
Содержание 1050 FME
Страница 2: ...FM FME 0904 35664_BA_FME_0904 book Seite 2 Montag 18 Mai 2009 10 09 10 ...
Страница 3: ...FM FME 0904 35664_BA_FME_0904 book Seite 3 Montag 18 Mai 2009 10 09 10 ...
Страница 167: ...Notizen Notes 167 Notizen 0904 Notizen_3Seiten fm Seite 167 Dienstag 19 Mai 2009 8 16 08 ...
Страница 168: ...168 Notizen Notes Notizen 0904 Notizen_3Seiten fm Seite 168 Dienstag 19 Mai 2009 8 16 08 ...
Страница 169: ...Notizen Notes 169 Notizen 0904 Notizen_3Seiten fm Seite 169 Dienstag 19 Mai 2009 8 16 08 ...