3

C.

 

Make sure you have adequate electrical supply.  LOW VOLTAGE WILL CAUSE BLOWER TO 
OVERHEAT AND DAMAGE MOTOR.  THIS VOIDS WARRANTY.     

 
 
D.

 

Keep insulation material from obstructing the cooling of motor. 

 
E.

 

Use only DRY cellulose.  Wet or damp material causes binding inside blower chamber and WILL 
OVERHEAT AND DAMAGE MOTOR.  THIS VOIDS WARRANTY. 

 
F.

 

If insulation hose or blower is clogged, turn blower off immediately, as continued operation WILL 
CAUSE BLOWER TO OVERHEAT AND DAMAGE MOTOR.  THIS VOIDS WARRANTY. 

 

MAINTENANCE. 

 

THIS  BLOWER  IS  BACKED  BY  A  ONE  (1)  YEAR  WARRANTY  AGAINST  MANUFACTURER’S 
DEFECTS.   If blower needs service during that time, call your supplier immediately.  Do not attempt to 
service blower, as this would void warranty. 
 
The manufacturer recommends that all repairs be made at its own factory authorized service center. Blower 
repair done by the manufacturer is warranted for 90 days on repair parts and workmanship.  
 
If  you  choose  to  have  repairs  made  elsewhere,  replacement  parts  are  offered  that  have  been  carefully 
inspected to insure they meet the specifications of the original part.  Any disassembly and reassembly of 
the  unit  to  replace  the  defective  part  must  be  done  with  care  to  insure  proper  fit  and  alignment.    No 
warranty consideration will be extended on parts incorrectly installed or mishandled.  All units should be 
run for approximately 15 minutes, prior to assembly of fan and chamber, to insure proper brush seating and 
alignment.  All questions regarding replacement of parts should be directed back to the factory. 
 

  

REGULAR BLOWER MAINTENANCE WILL EXTEND LIFE 
OF THE BLOWER.

   

 

A.

 

Always disconnect electrical power before making inspection or repairs. Quarterly inspection of 
the felt washers located under endplate is necessary to check for wear.  Failure to do so will result 
in bearing failure.  Daily blow out exhaust cooling fan and air intake fan on motor housing with 
compressed air to ensure bearing armature life. 

 
B.

 

Keep blower clean.  Check for accumulation of materials or debris on fan blades.  Make sure all 
material is blown out of blower at end of workday.  Weekly inspect the intake fan for bent or worn 
blades. 

 
C.

 

Keep motor clear of material for proper flow of cooling air. 

 
D.

 

Replace carbon brushes when worn to ½” in length.  Loosen brush plug (item #20), and remove 
the carbon brush (item #21).  There are two carbon brushes on motor.  Replace by inserting new 
brush in same direction.  Attach brush plug.  Use only Krendl carbon brushes.  These brushes are 
manufactured specifically for this motor.  Do not use substitute brushes as serious damage to the 
motor can be caused and VOID WARRANTY.  

 

 

 

 
 
 
 
 
 

Содержание 309

Страница 1: ...ersal brush type motor 309 16 8 amp Motor 120V 8 4 amp 230V 1 5 h p Motor No load RPM 16 500 2016 Watts CHAMBER FAN DIAMETER PRODUCTION AMPS SMALL 9 6 800 lbs hr 12 Chamber Outlet 2 or 2 MEDIUM 10 7 1000 lbs hr 15 Blower Intake 2 3 8 Fan bore 9 16 LIMITED WARRANTY This model carries a one 1 year warranty against defects in material and workmanship from date of invoice to the original purchaser If ...

Страница 2: ...TOR Never operate blower unless properly and securely mounted to machine Strong suction can pull fingers or clothing into dangerous blades Blower connects to insulation machine by a twist lock adapter 2 3 8 Ground properly with a three wire cord in a grounded electrical outlet Keep away from moisture Do not operate when flammable and or explosive vapors or dust are present Disconnect cord from ele...

Страница 3: ...proper fit and alignment No warranty consideration will be extended on parts incorrectly installed or mishandled All units should be run for approximately 15 minutes prior to assembly of fan and chamber to insure proper brush seating and alignment All questions regarding replacement of parts should be directed back to the factory REGULAR BLOWER MAINTENANCE WILL EXTEND LIFE OF THE BLOWER A Always d...

Страница 4: ...ct directly to power cord Blower unplugged Check all power connections Debris accumulated on brush Check to see if carbon brush assembly is making contact with the commutator Blow out area and keep clean Blower overheating high Low voltage Check length and gauge of amperage extension cord Material build up Clean excessive material from fan chamber by scraping and blowing out area Remove material f...

Страница 5: ...5 Excessive vibration Fan imbalance Clean material build up Inspect fan for broken blades Bearing failure Contact your supplier or qualified motor repair service ...

Страница 6: ... A KBL 025 KBL 026 A KBL 026 B KBL 026 M FSB016 KBL 028 A AL KBL 028 A STL KBL 028 B AL KBL 028 B STL FSB028 KBL 030 A 2 KBL 030 A 2 5 KBL 030 B 2 KBL 030 B 2 5 FSB009 KBL 033 FSB016 KBL 035 KBL 036 KBL 037 KBL 038 309 A KBL 038 309 B KBL 039 KBL 040 KBL 040 B KBL 043 KBL PIN DESCRIPTION BEARING BALL HOUSING BR END NAMEPLATE RETAININGRING ARMATURE ASSY 120V ARMATURE ASSY 230V CYLINDER FIELD ASSY 1...

Страница 7: ... 309 Blower Be sure to concentrate the air into the vent holes on both ends of the motor housing the brush end as well as the plate end of the motor housing Any build up of insulation in these vent holes can cause overheating and contamination of the motor housing voiding your warranty 2 Weekly Inspection of the intake fan is recommended to check for bent or worn blades Damaged blades can cause be...