KREMLIN REXSON
Page 9
Manual : 573.191.112
INSTALLATION DIAGRAM
B
A
Z1
Z2
Z2
1m
1m
2
3
4
5
8
B
6
6
7
7
1B
1A
1m
Z2
1B
1m
1A
A
Explosive area : area 1 (Z1) or area 2 (Z2)
(spray booth)
4
BASE pump
B
Non explosive area (safe area)
5
SOLVENT pump (base)
1A
CYCLOMIX
TM
MICRO control bay
6
Filter
1B
CYCLOMIX
TM
MICRO fluid module
7
Fluid pressure regulator
2
CATA pump
8
Gun
3
SOLVENT pump (cata)
Nota : To connect the SOLVENT pump (CATA) to the CYCLOMIX MICRO machine :
-
choose a machine set up with 1 catalyst and one cata solvent,
-
or disconnect the CATA hose at non-return valve level (CATA) of the machine and replace it connecting
the SOLVENT hose (CATA).
The 1 m distance indicated in the diagram is given for your information only and
KREMLIN REXSON shall not be liable for it. The user is liable for the exact
delimitation of the zones which depends on the materials used, the material
environment and the use conditions (refer to EN 60079 -10 standard).
The 1 m distance can be adapted if the analysis the user carries out calls for it.