TROUBLESHOOTING
For any intervention on the machine :
- Flush the circuits,
- Shut off the compressed air,
- Depressurize the hoses by triggering the gun,
- Shut off the electric supply.
If a problem occurs during the machine operation, alarms will be displayed on the screen of the machine.
Input
OK
to disable each alarm.
DIAGNOSTICS
ELECTRIC
FAULTS
CHECKINGS
Check that the isolating switch is on 'I'.
Check that the mains supply is connected.
No : connect it.
Check that the fuse on the electric card inside the
box is in working order.
No : change the fuse (ind. 3).
The machine does not switch on
Check the electric wiring of the supply cable (bad
contact or other)
TROUBLES
CAUSES
SOLUTIONS
Trouble on the BASE fluid section
Check the BASE circuit :
- material in the drum,
- suction rod strainer,
- pump valves.
Clean or change.
Check the CATALYST pressure towards
the BASE pressure.
Trouble on the CATALYST fluid
section
Check the CATALYST circuit :
- material in the drum,
- suction rod strainer,
- pump valves.
Clean or change.
Check the CATALYST pressure towards
the BASE pressure.
Incorrect mixing ratio
Flow incorrectly adjusted
Check the material levels in the supply
drums.
Check the starting of the pumps.
Check the CATALYST pressure towards
the BASE pressure.
Irrelevant data capture between the
ratio
and
the
injection
volume
(Machine
unable
to
give
the
parameters requested)
Check that the P1 parameter (ratio) and
the P6 parameter (injection volume) are
compatible in injection capability terms
in relation to the ratio requested.