10. INDICATIONS OF OPERATION GIVEN BY THE MACHINE
INDICATIONS GIVEN BY THE LEDS
Description
Function
Action
Red LED
Fault
The machine stops
Orange LED
Working
Function other than production (flushing, pot-
life alarm …)
Green LED
Production
Green + orange LED
Waiting
LED switched off
Programming
MESSAGES GIVEN BY THE DISPLAY UNIT
The messages given by the display unit are for your information only but do not stop the machine.
Number of cycles' overrun indication
Messages
Indications
Cyc.A
Overrun of the number of cycles configured at the P3 parameter
Cyc.b
Overrun of the number of cycles configured at the P14 parameter
Cyc.Ab
Overrun of the number of cycles configured at the P13 & P14 parameters
Fluids' consumption alarm
Messages
Indications
--A--
A fluid consumption alarm
A container empty
(volume fixed by the P8 parameter)
OK (during at least 3 seconds) : reset of low level pump shut off –A-
--b--
B fluid consumption alarm
B container empty
(volume fixed by the P9 parameter)
OK (during at least 3 seconds) : reset of low level pump shut off –B-