KREMLIN REXSON
- 3 -
N° : 578.070.120-UK-1402
3. INSTALLATION
The pumps are designed to be installed in a spray booth.
DESCRIPTION OF THE LABEL MARKING
Marking in accordance with
the ATEX Directive
KREMLIN REXSON
STAINS FRANCE
Name and address of the manufacturer
TYPE xx
Pump model
II 2 G
II
: group II
2
: class 2
Surface equipment meant to area where explosive atmospheres due to gas,
vapours, mists are liable to appear from time to time in usual operating
G
: gas
P prod : xx bar / xx psi
Maximum fluid pressure at the pump outlet
P air : 6 bar / 87 psi
Air supply maximum pressure of the pump motor
Serie / Serial
Number given by KREMLIN REXSON. The two first numbers indicate the
manufacturing year.
INSTALLATION INSTRUCTIONS
1
2
B
A
Z1
Z2
Z2
1m
1m
Ind.
Description
Ind.
Description
A
Explosive area
area 1 (Z1) or area 2 (Z2) : spray booth
1
Pump
B
Non explosive area
2
Spray gun