Krell S–1000
29
Set the SPL meter to C weighting and slow response. After initializ-
ing, the
LEFT
channel dB setting on the screen blinks, and you hear
band limited white noise through the left loudspeaker. This noise
continues for two seconds and then moves clockwise to the next
loudspeaker in the system.
While the individual channel on screen is blinking, use the direction
keys to adjust each loudspeaker’s setting until the SPL meter reads
75 dB.
Repeat this process with the remaining loudspeakers. When all the
loudspeakers are adjusted, press the previous key twice to return to
the main menu screen.
The adjustments must be made while the channel on screen is blinking.
Set the SPL meter to C weighting and slow response. After initializ-
ing, the cursor at the
LEFT
channel dB setting on the screen blinks.
Press enter. You hear banded white noise through the left loudspeak-
er.
While the individual channel on screen is blinking, use the direction
keys to adjust each loudspeaker’s setting until the SPL meter reads
75 dB.
Press enter to set each selection, then use the direction keys to
move to the next loudspeaker. Repeat this process for all loud-
speakers.
Press the previous key twice to return to the main menu screen.
Any loudspeaker not configured in the
SPEAKER SETUP
menu
displays
N/A
(not available) for the dB specification.
The program material option uses the same screen as the automatic
or manual noise sequence, but requires external program material
such as a test disc. The source plays, simultaneously, from all config-
ured loudspeakers. Use the enter and direction keys to individually
adjust loudspeaker levels based on your listening preferences rather
than SPL readings. If all channels are not present in the source mate-
rial, they will not be heard during this process.
System Configuration,
continued
Step 1, Listening Room Setup
Manual Noise Sequence
Program Material
Option
AUTO NOISE SEQUENCE
continued
Note
Note
Prev
Prev