Air System Prefi lter

An Air System Prefi lter is provided to maintain a clean, 
moisture-free supply of compressed air to the machine. The 
Air System Prefi lter reservoir should be routinely drained of 
moisture. To drain moisture from the reservoir either push the 
drain valve up toward the reservoir or to the side to use system 
air pressure to drain the collected fl uid. If the Air System 
Prefi lter reservoir needs to be removed to clean or replace the 
fi lter, make certain your machine is DISCONNECTED from the 
AIR SUPPLY. Cycle the machine via the foot switch several 
times to remove air from the system.

Air System Lubricator

An Air System Lubricator is provided to maintain proper 
lubrication to the pneumatic motor. The Air System Lubricator 
is fi lled with air motor oil and the Air System Lubricator 
comes preset at 1/2 turn open. The oil level in the Air System 
Lubricator should be routinely checked and refi lled with 
air motor oil comparable to the oil provided. Normal use of 
the machine will cause a light fi lm of oil to accumulate on 
the underside of the Top Plate where the pneumatic motor 
exhausts. Make certain your machine is DISCONNECTED 
from the AIR SUPPLY when fi lling the Air System Lubricator. 
Cycle the machine via the foot switch several times to 
remove air from the system.

Drain

Lubricator
Fill Cap

Содержание DK1100 FE

Страница 1: ...MMENDED AIR PRESSURES Electric Models 90 psi Pneumatic Models 120 psi 5 2010 DK1149 Rev C R Pro Series INSTRUCTIONAL MANUAL DK1100 Electric and Pneumatic Models DK3100 DK3100 DK1100 TP DK1100 FE DK110...

Страница 2: ...r Stock Thickness 11 Clamping Cyclinder Height Feed Rate Clamping Duration 12 Belt Tension 13 DK1100 TP FP Pnuematic Models 14 19 DK1100 TP FP QUICK START GUIDE 14 DK1100 TP FP PARTS DIAGRAM 15 Acryli...

Страница 3: ...ion or repairs required due to natural causes or acts of God To obtain warranty service contact the distributor from which this Pocket Hole Boring Machine was purchased or you may contact Kreg Tool Co...

Страница 4: ...aware of kickbacks Kickbacks occur when the workpiece binds up while being drilled causing it to twist jump and possibly become airborne To avoid kickbacks and potential injury always use sharp drill...

Страница 5: ...s that may affect its operation A guard or other part that is damaged should be properly repaired or replaced as soon as possible preceding any additional use Do not use the machine if you are not qua...

Страница 6: ...nez la machine avant d effectuer des ajustements N ajustez jamais le guide le dispositif anti oscillation le cylin dre de serrage la but e de profondeur de mortaise le foret ou tout autre l ment de la...

Страница 7: ...convenablement d s que possible avant tout autre usage N utilisez pas la machine si vous n tes pas qualifi pour effectuer ce genre d valuation Ne laissez jamais une machine en marche sans surveillance...

Страница 8: ...the risk of electric shock This tool is equipped with an electric cord having an equipment grounding conductor and a grounding plug The plug must be plugged into a matching outlet that is properly ins...

Страница 9: ...T RIVE 0ULLY YCLE OUNTER RILL IT RIVE SSEMBLY RILL HUCK RILL IT EPTH ONTROL DJUSTER EED 2ATE LOW ONTROL EPTH ONTROL 3WITCH RILL UIDE LOCK LAMP 0AD 3WING 3TOP LAMPING YLINDER LAMPING 4OWER DK1100 FE El...

Страница 10: ...0ULLY YCLE OUNTER RILL IT RIVE SSEMBLY RILL HUCK RILL ITS EPTH ONTROL DJUSTER EED 2ATE LOW ONTROL EPTH ONTROL 3WITCH RILL UIDE LOCK LAMP 0AD 3WING 3TOP LAMPING YLINDER LAMPING 4OWER IR ILTER IR AUGE D...

Страница 11: ...supply or electrical supply you can be certain the bit will not acciden tally engage while you are performing maintenance Step 1 Disconnect the machine from the air supply and or electrical supply St...

Страница 12: ...back into the resting position Lock Nut Depth Control Switch Head Depth Control Adjuster A Adjusting the Fence Setting The Fence can be adjusted to align the pocket hole to the center of material of d...

Страница 13: ...more clamping time Turning the Screw in the counter clockwise direction decreases the duration less clamping time Make certain to tighten the Locking Collar to prevent the Screw from accidentally drif...

Страница 14: ...machine is DISCONNECTED from the AIR SUPPLY and ELECTRICAL SUPPLY Cycle the machine via the foot switch several times to remove air from the system Without an air supply or electrical supply you can...

Страница 15: ...reg does not recommend the use of a long extension hose for use with this product Depending on the frequency of use Kreg recommends that you grease the planetary gear on the pneumatic drill at least o...

Страница 16: ...Y RILL HUCK RILL IT EPTH ONTROL DJUSTER EED 2ATE LOW ONTROL EPTH ONTROL 3WITCH RILL UIDE LOCK LAMP 0AD 3WING 3TOP LAMPING YLINDER LAMPING 4OWER IR ILTER IL UBRICATOR IR AUGE 0NEUMATIC OTOR EED 2ATE YL...

Страница 17: ...the Drill Chuck and into the Drill Guide Plate until the Drill Bit clears the Drill Chuck Angle the Drill Bit slightly and pull clear of the Drill Guide Plate Step 5 Insert a new or re sharpened Dril...

Страница 18: ...he Drill Depth Control Adjuster until the Head fully depresses the plunger on the Depth Control Switch Step 4 Tighten the Lock Nut to lock the Depth Control Adjuster in position Step 5 Pull the Drill...

Страница 19: ...djust the duration that the pneumatic clamp engages the material before during and after the drilling operation is performed The factory setting of this valve will maintain the correct amount of time...

Страница 20: ...t switch several times to remove air from the system Air System Lubricator An Air System Lubricator is provided to maintain proper lubrication to the pneumatic motor The Air System Lubricator is fille...